Viking™ Freedom Domed Residential Fire Sprinkler Cover Plate
Viking™ Freedom Domed Residential (Label No: 12194) White Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Viking™ fire sprinklers. The Freedom Domed cover facilitates timely activation of these Viking™ fire sprinkler heads with a temperature rating of 135F (57C). The outer diameter of this cover is 3-1/8 in. and protrudes 1 in. from the ceiling. This Viking™ cover plate is available with a 1/2 in. adjustment.
The Viking™ Freedom Domed cover plate is a residential cover plate used with compatible sprinklers. It provides a push-on connection into the sprinklers cup. This cover plate is available in nine finishes. These finishes include Painted White, Brushed Chrome, Polished Brass, Antique Brass, Brushed Brass, Brushed Copper, Ivory Painted, Black Painted, and Polished Chrome. Along with these base finishes, for an additional fee Viking™ will custom paint this cover in any finish you prefer. Contact QRFS™ customer support for more details.
Viking™ Freedom Domed Residential Cover Plate Sprinkler Head Compatibility and Listings
This Sprinkler Head Cover Plate from Viking™ may be listed by UL, FM, and/or other organizations depending on the sprinkler it’s being used with. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply pushing the cover into the sprinkler’s frame, and can be adjusted up to 1/2 in. The recommended hole diameter when installing sprinkler heads using this cover is 1-5/8 in.
To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.
When this fire sprinkler cover plate reaches its specified temperature of 135F (57C) the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.
Viking™ Freedom Domed Cover Plate Finishes, Temperatures, and Listed Accessories
This Viking™ Concealed sprinkler head cover plate fire sprinkler flat plate is available in Painted White, Brushed Chrome, Polished Brass, Antique Brass, Brushed Brass, Brushed Copper, Ivory Painted, Black Painted, and Polished Chrome. It is available at a temperature of 135F (57C). You can choose from all the available options by selecting from the dropdown at the top of the page. Find all related products in the Frequently Bought Together section above.
Viking™ is a leader in the fire protection manufacturing industry, with a variety of sprinkler heads, escutcheons, and cover plates.
This Sprinkler Cover Plate fits the following Viking™ concealed sprinkler heads:
- VK436
- VK438
- VK458
- VK466
- VK468
-
Sprinkler head cap