Need a replacement fire sprinkler system part? Our trained staff will help you find the right part, the first time. Call us at 888-361-6662.

Viking Model F-1 Recessed Escutcheon | 1/2" Sprinkler | Chrome | 06911AF

SKU
VK050F1CH
Viking Model F-1 Chrome Recessed Fire Sprinkler Escutcheon provides 1/2" of vertical adjustment with a non-split assembly. This 06911AF escutcheon installs to various fire sprinklers heads listed in this product's description.
$4.99
SKUFinishSprinkler Size (Orifice)Adjustment
VK050F1CH Chrome 1/2" (15 mm) NPT 1/2" (13 mm) with 1/4" (6 mm) Maximum Recess
DiameterDepth of Outer CupDepth of Center Adapter RingViking Part Number
3 1/16" (78 mm) 1 1/16" (27 mm) 1 7/16" (23/32" 06911AF
Fits ModelsAvailability
Various Usually Ships Within 48 Hours

Product Description

Viking Model F-1 Chrome Recessed Fire Sprinkler Escutcheon guarantees proper sprinkler head activation by covering the gap left by a hole saw when a fire sprinkler is installed. This recessed non-split escutcheon is sized for various fire sprinklers with a 1/2" (15 mm) NPT thread connection, and can adjust up to 1/2" (13 mm) with 1/4" (6 mm) maximum recess.

Viking Model F-1 Chrome Recessed Fire Sprinkler Escutcheon screws on to the fire sprinkler with National Pipe Thread (NPT) and may be installed only after shutting down the supply of water to sprinkler heads and removing the sprinklers to be fitted with this product. Viking's 06911AF escutcheon may be fitted to recessed pendent fire sprinklers with various sprinkler identification numbers (SINs), including:

  • VK003
  • VK004
  • VK008
  • VK015
  • VK023
  • VK102
  • VK104
  • VK110
  • VK112
  • VK116
  • VK132
  • VK134
  • VK158
  • VK159
  • VK162
  • VK164
  • VK169
  • VK170
  • VK180
  • VK181
  • VK182
  • VK186
  • VK188
  • VK202
  • VK206
  • VK212
  • VK254
  • VK279
  • VK290
  • VK292
  • VK302
  • VK303
  • VK304
  • VK305
  • VK307
  • VK308
  • VK317
  • VK318
  • VK319
  • VK320
  • VK329
  • VK330
  • VK331
  • VK332
  • VK333
  • VK334
  • VK342
  • VK343
  • VK344
  • VK346
  • VK352
  • VK353
  • VK360
  • VK377
  • VK430
  • VK432
  • VK435
  • VK436
  • VK438
  • VK440
  • VK442
  • VK446
  • VK448
  • VK450
  • VK452
  • VK453
  • VK458
  • VK460
  • VK466
  • VK468
  • VK4680
  • VK470
  • VK4700
  • VK472
  • VK479
  • VK484
  • VK4840
  • VK486
  • VK4860
  • VK534
  • VK536
  • VK537
  • VK572
  • VK600
  • VK601
  • VK602
  • VK603
  • VK604
  • VK605
  • VK606
  • VK607
  • VK608
  • VK609
  • VK610
  • VK611
  • VK612
  • VK613
  • VK617
  • VK630
  • VK631
  • VK910
More Information
Escutcheon Type Recessed
Escutcheon Fits Sprinkler Connection Size 1/2"
Escutcheon Finish Chrome
Escutcheon Retrofit No
Escutcheon Adjustable Yes
Escutcheon Adjustment 1/2"
Write Your Own Review
You're reviewing:Viking Model F-1 Recessed Escutcheon | 1/2" Sprinkler | Chrome | 06911AF