Viking™ VK110 Pendent Sprinkler | SR | 5.6K | White | 286F | 12972MG/W

SKU:
VK110WH286
Manufacturer Part Number:
12972MG/W
$39.99
  • Fire Sprinkler Wrench | Viking™ Frame-Style | Standard | 21475M/B | QRFS™ | Hero

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK110WH286
Manufacturer Part Number:
12972MG/W
Manufacturer:
Viking™
SIN:
VK110
Model:
Micromatic Model M
Head Type:
Pendent
Finish:
White
Finish Detail:
White-Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
286F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Copper Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light, Ordinary, Extra Hazard
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Sourced Location:
USA
Length:
1.25 in. (31.75 mm)
Width:
1.25 in. (31.75 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.153 lbs. (0.07 kg)

Viking™ VK110 Pendent Sprinkler | SR | 5.6K | White | 286F | 12972MG/W | QRFS™ | Hero

Overview

Viking™ Micromatic Model M Standard Response Pendent (VK110) Fire Sprinkler Head

Sprinkler Identification Number (SIN): VK110

This Pendent sprinkler features a White finish and 286F (141C) temperature.

This Viking™ Micromatic Model M Pendent Fire Sprinkler is a standard coverage Pendent fire sprinkler head, activating at 286F (141C) with a 5.6 K-Factor, and is rated for All Hazard occupancies (Light, Ordinary, Extra). Each Pendent head features a heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a brass frame with a copper deflector.

This is a standard response, standard coverage, Pendent sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The VK110 Micromatic Model M Sprinkler features a low profile and compact design. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.

Viking™ Micromatic Model M Fire Sprinkler VK110 Sprinkler Head Listings and Approvals

Each Micromatic Model M sprinkler is made by Viking™, a global leader in fire protection manufacturing. When installed properly, this VK110 fire sprinkler head maintains listings and approvals:

cULus, FM, CE

Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Viking™ Pendent Sprinkler VK110 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Pendent sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.

Viking™ (VK110) Micromatic Model M Pendent Sprinkler Installation and Other Information

The VK110 Pendent Sprinkler is installed exposed or surface mounted in the Pendent orientation. Refer to the manufacturer data sheet for installation instructions with the approved Viking™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Available finish options include Brass, White, Black, and Chrome.

Temperature options include 165F (74C), 220F (104C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK110 listed wrenches include the approved Viking™ Standard Sprinkler Wrench (21475M/B) and Viking™ Recessed Socket Wrench (13577W/B). Add the correct wrench for your VK110 pendent installation.

Other listed accessories include Viking™ sprinkler escutcheon and water shields, listed below and available at the top of this page. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools.

Available Viking™ VK110 Pendent Sprinklers & Listed Accessories:

Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Brass | 165F | 12972AC
Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Brass | 220F | 12972AF
Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Brass | 286F | 12972AG

Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Chrome | 165F | 12972FC
Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Chrome | 220F | 12972FF
Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Chrome | 286F | 12972FG

Viking™ VK110 Pendent Sprinkler | SR | 5.6K | White | 165F | 12972MC/W
Viking™ VK110 Pendent Sprinkler | SR | 5.6K | White | 220F | 12972MF/W
Viking™ VK110 Pendent Sprinkler | SR | 5.6K | White | 286F | 12972MG/W

Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Black | 165F | 12972MC/B
Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Black | 220F | 12972MF/B
Viking™ VK110 Pendent Sprinkler | SR | 5.6K | Black | 286F | 12972MG/B

Wrenches:
Viking™ Standard Sprinkler Wrench| 21475M/B | Pendent
Viking™ Recessed Socket Wrench | 13577W/B | Recessed Pendent

Escutcheons:
Viking™ E-1 Escutcheon| 1/2 in. Sprinkler | 06419
Viking™ E-2 Escutcheon | 1/2 in. Sprinkler | 11038

Reviews
No reviews yet
Product Alternatives