Fire Sprinkler Spare Head Cabinet | 24 Heads | Multiple Sizes Available!

SKU:
21-LN-SHC-24
Manufacturer Part Number:
100-375-00065
$71.99
  • Buy 10 - 49 and get 10% off
  • Buy 50 or above and get 20% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
21-LN-SHC-24
Manufacturer:
Lansdale™
Model:
Spare Head Cabinet
Number of Heads:
24 Heads
Material:
Steel
Sprinkler Size:
1/2 in. and 3/4 in. NPT
Head Type:
Pendent/Upright/Sidewall
Finish:
Red
UL Listed:
No
FM Approved:
No
Length:
7 in. (177.8 mm)
Width:
7 in. (177.8 mm)
Height:
1 in. (25.4 mm)
Weight:
0.7 lb. (0.32 kg)
Carton Quantity:
10

Fire Sprinkler Spare Head Cabinet | 24 Heads | Hero Image | QRFS™

Fire Sprinkler Spare Head Cabinet | 24 Heads | Hero Image | QRFS™
Fire Sprinkler Spare Head Cabinet | 24 Heads | Open Image | QRFS™
Fire Sprinkler Spare Head Cabinet | 24 Heads | Closed Image | QRFS™
Play Button
Overview

Fire Sprinkler 24 Spare Heads Cabinet

Keep your building compliant with a spare head cabinet – every building should have spare fire sprinkler heads in case of emergency! Fire sprinkler systems installed in accordance with NFPA 13 and NFPA 25 should have a supply of at least 6 spare fire sprinkler heads for a system with 300 or fewer sprinklers, 12 spare fire sprinkler heads for a system with 300 to 1000 fire sprinklers, and 24 fire sprinklers for a system with 1000 or more fire sprinklers.

This specific cabinet allows for storage of up to 24 spare heads, able to fit 1/2 in. NPT fire sprinkler heads, or, using the “knockouts,” 3/4 in. NPT heads. Your spare heads should have the same characteristics as the ones installed in your system: head type, orifice size, temperature rating, deflector type, and other design requirements.

Fire Sprinkler 24 Spare Head Cabinet Options & Additional Information

This fire sprinkler spare head cabinet is constructed of durable rolled steel and has a powder-coated red finish. It includes a full-length hinge and is slotted for easy mounting with screws, rivets, or strapping.

This spare head cabinet is available in multiple sizes – options include 3, 6, 12, 24, and 36 spare 1/2 in. or 3/4 in. heads, and 6 spare 3/4 in. or 1 in. heads for sprinkler systems with Early Suppression Fast Response (ESFR) heads.

Reviews
1 review |
1 review
  • 5

    Fire sprinkler head cabinet

    Posted by Michael Chew on Mar 21st 2023

    Easy to fit and managed to get all my spare sprinkler heads in no problem.

Product Alternatives