Reliable™ R1427 Upright Sprinkler | SR | 8.0K | Brass | 165F | 513A114498

SKU:
R1427BR165
Manufacturer Part Number:
513A114498
$89.70
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
R1427BR165
Manufacturer Part Number:
513A114498
Manufacturer:
Reliable™
SIN:
R1427
Model:
G Upright Intermediate
Head Type:
Upright
Finish:
Brass
Finish Detail:
Bronze
Size:
3/4 in.
Size Detail:
3/4 in. NPT Sprinkler
K Factor:
8.0K
Response Type:
Standard Response (SR)
Temperature:
165F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
3.125 in. (79.375 mm)
Width:
3.25 in. (82.55 mm)
Height:
3.125 in. (79.375 mm)
Weight:
0.64 lbs. (0.29 kg)
System Type:
Wet

Reliable™ R1427 Upright Sprinkler | SR | 8.0K | Brass | 165F | 513A114498

Reliable™ R1427 Upright Sprinkler | SR | 8.0K | Brass | 165F | 513A114498
Reliable™ R1427 Upright Sprinkler | SR | 8.0K | Brass | 165F | 513A114498
Reliable™ R1427 Upright Sprinkler | SR | 8.0K | Brass | 165F | 513A114498
Reliable™ R1427 Upright Sprinkler | SR | 8.0K | Brass | 165F | 513A114498
Overview

Reliable™ R1427BR165 Product Description

Reliable™ Model G Upright Intermediate Fire Sprinkler Head
Sprinkler Identification Number (SIN): R1427

This Upright sprinkler features a Brass finish and a 165°F (74°C) temperature.

This Reliable™ Model G Upright Intermediate Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 165°F with an 8.0 K-Factor. Each upright head features a fusible link heat element, Standard 3/4 in. NPT threads, and a brass frame with brass deflector.

This is a standard response, standard coverage, upright sprinkler with a maximum working water pressure of 175 PSI. Using a fusible link, this automatic fire sprinkler opens when ambient temperatures reach 165°F.

The R1427 is installed in the upright position. Refer to the manufacturer data sheet for installation instructions and orientation-specific limitations.


Reliable™ Upright Fire Sprinkler (R1427) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Reliable™, a manufacturer with a long-standing history of fire protection solutions. When installed properly, this R1427 maintains the following listings and approvals: UL Listed and FM Approved.

The Reliable™ Upright Sprinkler R1427 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet pipe fire protection systems.


Reliable™ R1427 Automatic Fire Sprinkler Installation and Accessories

During installation, be aware that over-tightening may cause permanent damage to the 3/4 in. NPT threads and/or the fire sprinkler itself. Use the manufacturer-approved installation wrench and tighten according to the specifications provided in the data sheet.

Listed R1427 Accessories include:
Guards and Shields:

  • Factory Water Shield (cULus, FM)

Sprinkler Wrench:

  • Model W2


Available Sprinklers in R1427 Family

  • Brass, 135°F

  • Brass, 165°F

  • Brass, 212°F

  • Brass, 286°F

Reviews
No reviews yet
Product Alternatives