Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Stainless Steel | 286F | AA281032R9

SKU:
RA6424SS286
Manufacturer Part Number:
AA281032R9
$449.67

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
RA6424SS286
Manufacturer Part Number:
AA281032R9
Manufacturer:
Reliable™
SIN:
RA6424
Model:
F1-56SS Upright
Head Type:
Upright
Finish:
Stainless Steel
Finish Detail:
Stainless Steel
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Standard Response (SR)
Temperature:
286F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Stainless Steel Frame, Stainless Steel Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
cULus Listed, CE, VdS
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
2.375 in. (60 mm)
Width:
1.375 in. (33 mm)
Height:
2.375 in. (60 mm)
Weight:
lbs. (0 kg)
System Type:
Wet

Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Stainless Steel | 286F | AA281032R9

Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Stainless Steel | 286F | AA281032R9
Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Stainless Steel | 286F | AA281032R9 | Side
Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Stainless Steel | 286F | AA281032R9 | Alt Side
Reliable™ RA6424 Upright Sprinkler | SR | 5.6K | Stainless Steel | 286F | AA281032R9 | Deflector
Overview

Reliable™ RA6424SS286 Product Description

Reliable™ Model F1-56SS Upright Fire Sprinkler Head
Sprinkler Identification Number (SIN): RA6424

This Upright sprinkler features a Stainless Steel finish and a 286°F (141°C) temperature rating.

The Reliable™ Model F1-56SS Upright Fire Sprinkler is a standard response, standard coverage sprinkler with a 5.6 K-Factor. It includes a 3 mm heat-sensitive glass bulb, 1/2 in. NPT thread connection, and a stainless steel frame with a stainless steel deflector. The finish is Stainless Steel.

This upright sprinkler is rated for a maximum working pressure of 175 PSI and operates using a glass bulb that activates at 286°F.

The RA6424 must be installed in an upright position and in accordance with the instructions provided in the Reliable™ technical bulletin.


Reliable™ Upright Fire Sprinkler (RA6424) Listings and Approvals

Each RA6424 sprinkler is manufactured by Reliable™ and meets the following listings and approvals:

  • UL Listed

  • cULus Listed

  • FM Approved

  • CE Marked

  • VdS Approved


RA6424 Upright Sprinkler – Design Specifications

The RA6424SS286 is intended for use in NFPA 13-compliant fire protection systems. It is suitable for wet pipe systems and carries a maximum working water pressure rating of 175 PSI (12.1 BAR). For detailed coverage areas, installation requirements, and hydraulic calculations, refer to the Reliable™ data sheet.


RA6424 Installation and Accessories

To avoid damaging the 1/2 in. NPT threads or sprinkler frame, use only the manufacturer-approved installation wrench. Follow torque specifications and installation guidance outlined in the technical bulletin.

Approved Accessories:

Sprinkler Wrench:

  • Model W2

Guards and Shields:

  • D-1 Guard (cULus)

  • D-3 Guard & Shield (cULus)

  • C-1 Guard (FM – available in type 316 stainless steel)

  • C-3 Guard & Shield (cULus, FM)

Note: The above guard and shield accessories are not corrosion-resistant unless otherwise noted.


Available RA6424 Sprinkler Heads

This sprinkler head is available in Stainless Steel finish with the following temperature options:

  • 135°F (57°C)

  • 155°F (68°C)

  • 175°F (79°C)

  • 200°F (93°C)

  • 286°F (141°C)

  • 360°F (182°C)

  • 500°F (260°C)