Tyco™ TY3531 Concealed Pendent Sprinkler | QR | 5.6K | 155F | 51-792-1-155

SKU:
TY3531CP155
Manufacturer Part Number:
51-792-1-155
$50.79
    • Buy 100 - 199 and get 3% off
    • Buy 200 or above and get 7% off

    FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

    RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

    Specifications
    QRFS™ SKU:
    TY3531CP155
    Manufacturer Part Number:
    51-792-1-155
    Manufacturer:
    Tyco™
    SIN:
    TY3531
    Model:
    RFII
    Head Type:
    Concealed Pendent
    Size:
    1/2 in.
    Size Detail:
    1/2 in. NPT Sprinkler
    K Factor:
    5.6K
    Response Type:
    Quick Response (QR)
    Temperature:
    155F
    Heat Element:
    Glass Bulb
    Coverage:
    Standard Coverage
    Material:
    Bronze Frame, Bronze Deflector
    Corrosion Resistant:
    No
    May Contain Lead:
    Yes
    UL Listed:
    Yes
    FM Approved:
    Yes
    Maximum Working Water Pressure:
    175 PSI (UL, FM) 250 PSI (UL)
    Length:
    3.25 in. (82.55 mm)
    Width:
    3.25 in. (82.55 mm)
    Height:
    2.94 in. (74.68 mm)
    Weight:
    0.4 lb. (0.18 kg)
    Finish:
    Brass

    Tyco™ TY3531 Concealed Pendent | 155F | 51-792-1-155 | Hero

    RFII line
    Tyco™ TY3531 Concealed Pendent | 155F | 51-792-1-155 | Hero
    Tyco™ TY3531 Concealed Pendent | 155F | 51-792-1-155 | With Cover
    Tyco™ TY3531 Concealed Pendent | 155F | 51-792-1-155 | Deflector
    Play Button
    Overview

    Tyco™ RFII (TY3531) Quick Response Concealed Pendent Fire Sprinkler

    This Tyco™ RFII Concealed Pendent Quick Response fire sprinkler features a glass bulb activating at 155F (68C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each concealed pendent sprinkler head features a bronze frame and deflector. This sprinkler was designed to be covered by a Tyco™ RFII cover plate, allowing for optimal aesthetics and proper function. The manufacturer part number is 51-790-1-155 and the Sprinkler Identification Number (SIN) is TY3531.

    The RFII Sprinkler delivers decorative, affordable defense against fire. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin. This model has a 5.6 K-factor. These sprinklers are optimal for architecturally sensi­tive areas such as hotel lobbies, office buildings, churches, and restaurants.

    Tyco™ RFII (TY3531) Quick Response Concealed Fire Sprinkler Head Listings and Approvals

    Each RFII sprinkler is made by Tyco™, a global leader in fire-suppression products. This concealed fire sprinkler head maintains UL Listing and is FM Approved as Standard Response.

    The TY3531 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial areas. This concealed pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL Listed and connects to ceiling wet piping systems.

    Tyco™ RFII (TY3531) Quick Response Concealed Pendent Head Sprinkler Installation and Other Information

    During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

    This concealed sprinkler head is available at a temperature of 155 (68C) or 200F (93C) and must be paired with a Tyco™ RFII Cover Plate. 139F (59C) cover plates are designed for use with the 155F sprinkler and come in a variety of finishes: Grey White, Brushed Brass, Brass, Signal White, Jet Black, Terra Brown, Brushed Chrome, and Polished Chrome. To choose your cover plate, find the “Options” section at the top of this product page.

    Along with the required Cover Plate, TY3531 listed accessories include the RFII sprinkler wrench, manufacturer part number (56-000-1-075) and the Tyco™ Air and Dust Seal, manufacturer part number (56-908-1-001). This sprinkler head is commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

    Reviews
    No reviews yet
    Product Alternatives