Tyco™ TY4851 Upright Sprinkler | SR | 8.0K | White | 135F | 57-560-4-135

SKU:
TY4851WH135
Manufacturer Part Number:
57-560-4-135
$51.36

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
TY4851WH135
Manufacturer Part Number:
57-560-4-135
Manufacturer:
Tyco™
SIN:
TY4851
Model:
TY-B
Head Type:
Upright
Finish:
White
Finish Detail:
Signal White Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT
K Factor:
8.0K
Response Type:
Standard Response (SR)
Temperature:
135F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Bronze Frame, Copper Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
EAC Approved, LPCB, VdS Approved
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
1.5 in. (38.1 mm)
Width:
1.5 in. (38.1 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.13 lbs. (0.06 kg)

Tyco™ TY4851 White 135F SR Upright 57-560-4-135 Hero Image | QRFS™

Tyco™ TY4851 White 135F SR Upright 57-560-4-135 Hero Image | QRFS™
Tyco™ TY4851 White 135F SR Upright 57-560-4-135 Side Image | QRFS™
Tyco™ TY4851 White 135F SR Upright 57-560-4-135 Alt Side Image | QRFS™
Tyco™ TY4851 White 135F SR Upright 57-560-4-135 Hero Image | QRFS™
Overview

Tyco™ Model TY-B Upright Fire Sprinkler Head

Sprinkler Identification Number (SIN): TY4851

This Upright sprinkler features a White finish and a 135°F (57°C) temperature.

This Tyco™ Model TY-B Upright Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 135°F with a 8.0 K-Factor. Each upright head features a heat-sensitive 5 mm glass bulb, Standard 1/2 in. NPT threads, and a Bronze frame with Copper deflector.

This is a standard response, standard coverage, upright sprinkler with a maximum working water pressure of 175 PSI. Using a heat-activated glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 135°F, effectively containing the spread of fire.

The TY4851 is installed in the upright position. Refer to the manufacturer data sheet for installation instructions.

Tyco™ Upright Fire Sprinkler (TY4851) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Tyco™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this TY4851 maintains the following listings and approvals: UL, C-UL, FM, LPCB, EAC
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Tyco™ Upright Sprinkler TY4851 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet pipe fire protection systems.

Tyco™ TY4851 Automatic Fire Sprinkler Installation and Accessories

During installation, be aware that over-tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer-approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Listed TY4851 Accessories include:

Sprinkler Wrenches:

  • W-Type 6 Standard Sprinkler Wrench

 

Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These are available in the corresponding product category sections.

Available Sprinklers

This upright sprinkler head is also available in Black, Brass, and Chrome finishes and in 155F, 175F, 200F, 286F, and 360F temperature options.

Reviews
No reviews yet
Product Alternatives