Victaulic™ V56 Cover Plate | Black | 135F | 2-1/4 in. ID | S110NA00BO

SKU:
11-V-V56-BL135
Manufacturer Part Number:
S110NA00BO
$45.75
  • Buy 50 - 99 and get 2.5% off
  • Buy 100 or above and get 7.5% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
11-V-V56-BL135
Manufacturer Part Number:
S110NA00BO
Manufacturer:
Victaulic™
Model:
V56
Installation Type:
Push On or Thread On
Adjustment:
1 in.
Outer Diameter:
3-5/16 in.
Inner Diameter:
2-1/4 in.
Finish:
Black
Finish Detail:
Black Painted
Temperature:
135F
Corrosion Resistant:
No
UL Listed:
Yes
FM Approved:
Yes
Weight:
0.18 lb. (0.08 kg)

Victaulic™ V56 Cover Plate | Black | 135F | 2-1/4 in. ID | S110NA00BO

Victaulic™ V56 Cover Plate | Black | 135F | 2-1/4 in. ID | S110NA00BO
Victaulic™ V56 Cover Plate | Black | 135F | 2-1/4 in. ID | S110NA00BO
Victaulic™ V56 Cover Plate | Black | 135F | 2-1/4 in. ID | S110NA00BO
Victaulic™ V56 Cover Plate | Black | 135F | 2-1/4 in. ID | S110NA00BO
Overview

Victaulic™ V56 Fire Sprinkler Cover Plate

Victaulic™ V56 Black Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Victaulic™ concealed pendent and dry fire sprinklers.  The V56 cover facilitates timely activation of these concealed fire sprinkler heads with a temperature rating of 135F (57C). See below for compatible sprinkler heads. This sprinkler cover has an outer diameter of 3-5/16 in.

Victaulic™ V56 Fire Sprinkler Head Cover Plate Compatibility and Listings

This Sprinkler Head Cover Plate from Victaulic™ is UL Listed, and/or may be listed/approved by other organizations depending on the sprinkler. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply screwing the cover into the sprinkler’s frame.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this fire sprinkler cover plate reaches its specified temperature of 135F, the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

This Sprinkler Cover Plate fits the following Victaulic™ concealed sprinkler heads:

  • V1106
  • V4906
  • V5603
  • V5634
  • V5689
  • V8134
  • V8189