SALE

Viking™ VK377 Pendent Sprinkler | QR | 11.2K | Chrome | 155F | 08337FB

SKU:
VK377CH155
Manufacturer Part Number:
08337FB
$62.99
$44.09
  • Viking™ E-1 Escutcheon | Polished Chrome | 3/4 in. Sprinkler | QRFS™ | Hero
  • Viking™ E-2 Escutcheon | Polished Chrome | 3/4 in. Sprinkler | QRFS™ | Hero
  • Viking™ E-3 Escutcheon | Polished Chrome | 3/4 in. Sprinkler | QRFS™ | Hero
  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK377CH155
Manufacturer Part Number:
08337FB
Manufacturer:
Viking™
SIN:
VK377
Model:
ELO
Head Type:
Pendent
Finish:
Chrome
Finish Detail:
Chrome
Size:
3/4 in.
Size Detail:
3/4 in. NPT Sprinkler
K Factor:
11.2K
Response Type:
Quick Response (QR)
Temperature:
155F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed or Surface Mounted
Length:
1.25 in. (31.75 mm)
Width:
1.25 in. (31.75 mm)
Height:
2.31 in. (58.67 mm)
Weight:
0.4 lb. (0.18 kg)

Viking™ VK377 Pendent Sprinkler | QR | 11.2K | Chrome | 155F | 08337FB | QRFS™ | Hero

Viking™ VK377 Pendent Sprinkler | QR | 11.2K | Chrome | 155F | 08337FB | QRFS™ | Hero
Viking™ VK377 Pendent Sprinkler | QR | 11.2K | Chrome | 155F | 08337FB | QRFS™ | Side
Viking™ VK377 Pendent Sprinkler | QR | 11.2K | Chrome | 155F | 08337FB | QRFS™ | Family
Overview

Viking™ ELO Quick Response Pendent (VK377) (Storage-Density/Area) Fire Sprinkler Head

This Viking™ ELO (Extra Large Orifice) QR Pendent Fire Sprinkler features a glass bulb activating at 155F (68C) with a 11.2 K-Factor, and 3/4 in. NPT threads. Each horizontal sidewall head features a brass frame and brass deflector. The Sprinkler Identification Number (SIN) is VK377. This is a quick response sprinkler with a maximum working water pressure of 175 PSI.

The VK377 pendent sprinkler delivers effective, affordable defense against fire in hazard occupancies up to and including Ordinary Group II (UL). Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin. For recessed application, refer to data sheet for installation instructions with the approved Viking™ escutcheon(s).

Viking™ ELO Pendent Fire Sprinkler Quick Response (VK377) Sprinkler Head Listings and Approvals

Each ELO pendent sprinkler is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VNIV), FM (Class 2009), LPCB (Certificate 096e/14), and VdS (Certificate G413049, G413051). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

Quick Response Extra-Large Orifice Pendent Sprinkler VK377 is cULus Listed for installation in accordance with the latest edition of NFPA 13 for standard pendent spray sprinklers. Designed for use in hazard occupancies up to and including Ordinary Hazard Group II with a minimum operating pressure of 7 psi (0.5 bar). Also cULus Listed for use in High-Piled Storage Occupancies as defined in NFPA 13 with a minimum operating pressure of 7 psi (0.5 bar). Listed only for use in wet pipe sprinkler systems (or preaction systems qualifying as wet systems). The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed.

Sprinkler VK377 is FM Approved as a quick response pendent Storage sprinkler. Approved storage sprinklers are also FM Approved for use as non-storage sprinklers.

This extra-large orifice pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL, FM and connects to wet piping systems.

Viking™ ELO QR Pendent (VK377) Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 3/4 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 20 ft-lb (27.1 N-m). Refer to the data sheet for additional storage and installation information.

This pendent

sprinkler features a chrome finish and a 155F (68C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 155F (68C), 175F (79C), 200F (93C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK377 listed accessories include the approved Viking™ Wrench (part no. 05118CW/B), Viking™ Recessed Wrench (part no. 11663W/B), and the approved Viking™ Escutcheon(s). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Reviews
No reviews yet
Product Alternatives