*OBSOLETE* Viking™ Freedom Concealed Horizontal Sidewall Fire Sprinkler | VK4800 | Residential | 4.0K | 165F | Lead Free | 16880AC

SKU:
VK4800CS165
Manufacturer Part Number:
16880AC
$87.64
Data Sheet Product Data Sheet

Select Variation

  • Buy 50 - 199 and get 3% off
  • Buy 200 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK4800CS165
May Contain Lead:
No
Nominal K-Factor:
4.0K
Fire Sprinkler Heat Element:
Fusible Link
Fire Sprinkler Use Type:
Residential
Fire Sprinkler Head Type:
Concealed Horizontal Sidewall
SIN:
VK4800
Thread Type:
NPT
Model:
Freedom
UL Listed/FM Approved:
No
Finish:
Brass
Finish Detail:
Brass

*OBSOLETE* Viking™ Freedom Concealed Horizontal Sidewall Fire Sprinkler | VK4800 | Residential | 4.0K | 165F | Lead Free | 16880AC

*OBSOLETE* Viking™ Freedom Concealed Horizontal Sidewall Fire Sprinkler | VK4800 | Residential | 4.0K | 165F | Lead Free | 16880AC
*OBSOLETE* Viking™ Freedom Concealed Horizontal Sidewall Fire Sprinkler | VK4800 | Residential | 4.0K | 165F | Lead Free | 16880AC
*OBSOLETE* Viking™ Freedom Concealed Horizontal Sidewall Fire Sprinkler | VK4800 | Residential | 4.0K | 165F | Lead Free | 16880AC
*OBSOLETE* Viking™ Freedom Concealed Horizontal Sidewall Fire Sprinkler | VK4800 | Residential | 4.0K | 165F | Lead Free | 16880AC
*OBSOLETE* Viking™ Freedom Concealed Horizontal Sidewall Fire Sprinkler | VK4800 | Residential | 4.0K | 165F | Lead Free | 16880AC
Data & Resources
Overview

Viking™ V4800 Residential Fast Response Concealed Horizontal Sidewall Fire Sprinkler delivers decorative, competitively-priced defense against fire in residential occupancies such as homes and apartments. Using a heat-activated soldered link and lever assembly, this automatic fire sprinkler opens when ambient temperatures reach 165F (74C), reducing the likelihood of flashover and facilitating safe evacuation.

The included low-profile cover plate mounts flush to nearby walls and is available in a custom finish by special order or in one nine standard finishes, including: white, ivory, black, antique brass, brushed brass, brushed chrome, bright brass, polished chrome, or brushed copper. When temperatures near the ceiling reach 135F (57C), the soldered cover plate detaches, exposing the head of the Viking™ VK4800 concealed horizontal sidewall fire sprinkler, which activates when temperatures reach 165F (74C).

The Viking™ Model V4800 has a 4.0 K-Factor and installs with 1/2 in. (12.7 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Residential Fast Response Fire Sprinkler features a lead-free design in compliance with the Reduction of Lead in Drinking Water Act, including a brass body, brass deflector ring, and a nickel-alloy sealing assembly with PFTE. This fire sprinkler features up to 1/4 in. (6.4 mm) of adjustment and includes a p.

To order the Viking™ V4800 with custom cover plates, contact us at 888.361.6662 or fill out our contact form.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model V4800 sprinkler is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years.

This product is UL-listed, and appropriate for use in fire protection systems when accepted by the authority having jurisdiction.

*OBSOLETE* Sprinkler is no longer manufactured. This Sprinkler has been replaced by the VK480CS165.