Viking™ VK302 Microfast Pendent Sprinkler | QR | 5.6K | Black | 175F | 1/2 in. NPT | 12979MD/B

SKU:
VK302BL175
Manufacturer Part Number:
12979MD/B
$13.75

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK302BL175
Manufacturer Part Number:
12979MD/B
Manufacturer:
Viking™
SIN:
VK302
Model:
Microfast
Head Type:
Pendent
Finish:
Black
Finish Detail:
Black Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light, Ordinary Hazard
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Height:
2.25 in. (57.2 mm)

Viking™ VK302 Microfast Pendent Sprinkler | QR | 5.6K | Black | 175F | 1/2 in. NPT | 12979MD/B | QRFS™ | Hero

Overview

Viking™ Microfast Quick Response Pendent (VK302) Fire Sprinkler Head

Sprinkler Identification Number (SIN): VK302

*SPRINKER SIN VK302 IS OBSOLETE*
*SIN VK302 has been replaced by SIN VK3021*

This Pendent sprinkler features a Black finish and 175F (79C) temperature.

This Viking™ Microfast Pendent Fire Sprinkler is a standard coverage pendent fire sprinkler head, activating at 175F (79C) with a 5.6 K-Factor, and is rated for Light and Ordinary Hazard occupancies. Each Pendent head features a heat-sensitive glass bulb assembly, standard 1/2 in. NPT threads, and a brass frame with a bronze deflector.

This is a quick response, standard coverage pendent sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The VK302 Microfast Sprinkler offers reliable fire protection with a sleek, unobtrusive profile. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.

Viking™ Microfast Fire Sprinkler VK302 Sprinkler Head Listings and Approvals

Each Microfast sprinkler is made by Viking™, a global leader in fire protection manufacturing. When installed properly, this VK302 fire sprinkler head maintains listings and approvals:

cULus, FM, VdS, LPCB, CE, China GB, MED Certified

Refer to the datasheet for up-to-date listings and approvals in specific temperatures and/or applications.

When using Viking™ Pendent Sprinkler VK302 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Pendent sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.

Viking™ (VK302) Microfast Pendent Sprinkler Installation and Other Information

The VK302 Pendent Sprinkler is installed surface mounted or recessed in the pendent orientation. Refer to the manufacturer data sheet for installation instructions with the approved Viking™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Available finish options include Brass, Chrome, White, and Black.
Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), 286F (141C).

The VK302 listed wrenches include the approved Viking™ Standard Sprinkler Wrench (21475M/B) and the Viking™ Recessed Pendent Sprinkler Wrench (13655W/B). Add the correct wrench for your VK302 Pendent installation!

The VK302 listed escutcheons include the Viking™ E-1 Escutcheon, E-2 Escutcheon, and E-3 Escutcheon.
Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools.

Available Viking™ VK302 Pendent Sprinklers & Listed Accessories:

Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Brass | 135F | 1/2 in. NPT | 12979AA
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Brass | 155F | 1/2 in. NPT | 12979AB
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Brass | 175F | 1/2 in. NPT | 12979AD
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Brass | 200F | 1/2 in. NPT | 12979AE
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Brass | 286F | 1/2 in. NPT | 12979AG

Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Chrome | 135F | 1/2 in. NPT | 12979FA
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Chrome | 155F | 1/2 in. NPT | 12979FB
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Chrome | 175F | 1/2 in. NPT | 12979FD
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Chrome | 200F | 1/2 in. NPT | 12979FE
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Chrome | 286F | 1/2 in. NPT | 12979FG

Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | White | 135F | 1/2 in. NPT | 12979MA/W
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | White | 155F | 1/2 in. NPT | 12979MB/W
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | White | 175F | 1/2 in. NPT | 12979MD/W
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | White | 200F | 1/2 in. NPT | 12979ME/W
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | White | 286F | 1/2 in. NPT | 12979MG/W

Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Black | 135F | 1/2 in. NPT | 12979MA/B
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Black | 155F | 1/2 in. NPT | 12979MB/B
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Black | 175F | 1/2 in. NPT | 12979MD/B
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Black | 200F | 1/2 in. NPT | 12979ME/B
Viking™® VK302 Microfast Pendent Sprinkler | QR | 5.6K | Black | 286F | 1/2 in. NPT | 12979MG/B


Wrenches:
Viking™ Standard Sprinkler Wrench | 21475M/B | Pendent
Viking™ Pendent/Domed HSW | Recessed/Concealed | 13655W/B

Escutcheons:
Viking™ E-1 Escutcheon | E1ST
Viking™ E-2 Escutcheon | E2ST
Viking™ E-3 Escutcheon | E3ST

Reviews
No reviews yet
Product Alternatives