Viking™ VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 200F | 3/4 in. NPT | 15591AE

SKU:
VK360BR200
Manufacturer Part Number:
15591AE
$18.99
  • Fire Sprinkler Wrench | Viking™ Frame-Style | Standard | 21475M/B | QRFS™ | Hero
  • Viking™ E-1 Escutcheon | White Stainless | 3/4 in. Sprinkler | QRFS™ | Hero
  • Viking™ E-1 Escutcheon | Chrome Stainless | 3/4 in. Sprinkler | QRFS™ | Hero
  • Viking™ E-2 Escutcheon | White Polyester | 3/4 in. Sprinkler | QRFS™ | Hero
  • Viking™ E-2 Escutcheon | Polished Chrome | 3/4 in. Sprinkler | QRFS™ | Hero
  • Viking™ G-1 Escutcheon | White Polyester | 3/4 in. Sprinkler | QRFS™ | Hero
  • Viking™ G-1 Escutcheon | Polished Chrome | 3/4 in. Sprinkler | QRFS™ | Hero

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK360BR200
Manufacturer Part Number:
15591AE
Manufacturer:
Viking™
SIN:
VK360
Model:
Microfast Model M
Head Type:
Horizontal Sidewall
Finish:
Brass
Finish Detail:
Standard Brass
Size:
3/4 in.
Size Detail:
3/4 in. NPT Sprinkler
K Factor:
8.0K
Response Type:
Quick Response (QR)
Temperature:
200F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light, Ordinary Hazard
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
1.45 in. (36.8 mm)
Width:
1.45 in. (36.8 mm)
Height:
2.6 in. (66.0 mm)
Weight:
0.21 lbs. (0.10 kg)

Viking™ VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 200F | 3/4 in. NPT | 15591AE | QRFS™ | Hero

Viking™ VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 200F | 3/4 in. NPT | 15591AE | QRFS™ | Hero
Viking™ VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 200F | 3/4 in. NPT | 15591AE | QRFS™ | Front
Viking™ VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 200F | 3/4 in. NPT | 15591AE | QRFS™ | Deflector
Viking™ VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 200F | 3/4 in. NPT | 15591AE | QRFS™ | Side
Overview

Viking™ Microfast Model M Quick Response Horizontal Sidewall (VK360) Fire Sprinkler Head

Sprinkler Identification Number (SIN): VK360

This Horizontal Sidewall sprinkler features a Brass finish and 200F (93C) temperature.

This Viking™ Microfast Model M Horizontal Sidewall Fire Sprinkler is a quick response, standard coverage Horizontal Sidewall fire sprinkler head, activating at 200F (93C) with a 8.0 K-Factor, and is rated for Light and Ordinary Hazard occupancies. Each Horizontal Sidewall head features a heat-sensitive glass bulb assembly, standard ¾ in. NPT threads, and a brass frame with a brass deflector.

This is a quick response Viking™ Horizontal Sidewall sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The VK360 Microfast Model M Sprinkler offers reliable fire protection with a sleek, unobtrusive profile. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.

Viking™ Microfast Model M Fire Sprinkler VK360 Sprinkler Head Listings and Approvals

Each Microfast Model M sprinkler is made by Viking™, a global leader in fire protection manufacturing. When installed properly, this VK360 fire sprinkler head maintains listings and approvals:

cULus

Refer to the datasheet for up-to-date listings and approvals in specific temperatures and/or applications.

When using Viking™ Horizontal Sidewall Sprinkler VK360 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Horizontal Sidewall sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.

Viking™ (VK360) Microfast Model M Horizontal Sidewall Sprinkler Installation and Other Information

The VK360 Horizontal Sidewall Sprinkler is installed surface mounted or recessed in the Horizontal Sidewall orientation. Refer to the manufacturer data sheet for installation instructions with the approved Viking™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Available finish options include Brass, Chrome, White, and Black.
Temperature options include 135F (57C), 155F (68C), 175F (79C), and 200F (93C).

White and Black Polyester Finish are cULus Listed as corrosion resistant.

The VK360 listed wrenches include the approved Viking™ Standard Sprinkler Wrench (21475M/B) and the Viking™ Recessed Horizontal Sidewall Sprinkler Wrench (13655W/B). Add the correct wrench for your VK360 Horizontal Sidewall installation!

The VK360 listed escutcheons include the Viking™ E-1, E-2, and G-1 Recessed Escutcheons.
Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools.

Available Viking™ VK360 Horizontal Sidewall Sprinklers & Listed Accessories:

Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 135F | 3/4 in. NPT | 15591AA
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 155F | 3/4 in. NPT | 15591AB
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 175F | 3/4 in. NPT | 15591AD
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Brass | 200F | 3/4 in. NPT | 15591AE

Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Chrome | 135F | 3/4 in. NPT | 15591FA
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Chrome | 155F | 3/4 in. NPT | 15591FB
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Chrome | 175F | 3/4 in. NPT | 15591FD
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Chrome | 200F | 3/4 in. NPT | 15591FE

Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | White | 135F | 3/4 in. NPT | 15591MA/W
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | White | 155F | 3/4 in. NPT | 15591MB/W
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | White | 175F | 3/4 in. NPT | 15591MD/W
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | White | 200F | 3/4 in. NPT | 15591ME/W

Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 135F | 3/4 in. NPT | 15591MA/B
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 155F | 3/4 in. NPT | 15591MB/B
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 175F | 3/4 in. NPT | 15591MD/B
Viking™® VK360 Microfast Model M Horizontal Sidewall Sprinkler | QR | 8.0K | Black | 200F | 3/4 in. NPT | 15591ME/B

Wrenches:
Viking™ Standard Sprinkler Wrench | 21475M/B | Pendent
Viking™ Pendent/Domed HSW | Recessed/Concealed | 13655W/B

Escutcheons:
Viking™ E-1 Escutcheon | E1ST
Viking™ E-2 Escutcheon | E2ST
Viking™ G-1 Escutcheon | G1ST

Reviews
No reviews yet
Product Alternatives