Viking™ VK4621 Concealed Pendent Sprinkler | QR | 5.6K | 200F | 24682AE

SKU:
VK4621CP200
Manufacturer Part Number:
24682AE
$28.99
  • Viking™ Mirage Cover Plate | White | 165F | 2-3/4 in. OD | QRFS™ | Hero
  • Viking™ Mirage Cover Plate | White | 165F | 3-5/16 in. OD | QRFS™ | Hero
  • FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

    RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

    Specifications
    QRFS™ SKU:
    VK4621CP200
    Manufacturer Part Number:
    24682AE
    Replaces Manufacturer Part Numbers:
    22961AE, 13503AE
    Manufacturer:
    Viking™
    SIN:
    VK4621
    Model:
    XT1
    Head Type:
    Concealed Pendent
    Size:
    1/2 in.
    Size Detail:
    1/2 in. NPT Sprinkler
    K Factor:
    5.6K
    Response Type:
    Quick Response (QR)
    Temperature:
    200F
    Heat Element:
    Glass Bulb
    Coverage:
    Standard Coverage
    Material:
    Brass Body. Bronze Deflector
    Corrosion Resistant:
    No
    May Contain Lead:
    Yes
    UL Listed:
    Yes
    FM Approved:
    Yes
    Maximum Working Water Pressure:
    175 PSI (UL, FM) 250 PSI (UL)
    Length:
    2.25 in. (57.15 mm)
    Width:
    2.25 in. (57.15 mm)
    Height:
    2.5 in. (63.5 mm)
    Weight:
    0.3 lb. (0.14 kg)
    Finish:
    Brass

    Viking™ VK4621 Concealed Pendent Sprinkler | QR | 5.6K | 200F | 24682AE | Hero | QRFS™

    Replaces VK462
    Play Button
    Overview

    Viking™ Quick Response Concealed Pendent (VK4621) Fire Sprinkler Head

    This Viking™ Concealed Pendent Fire Sprinkler features a glass bulb activating at 200F (93C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each concealed pendent head features a bronze deflector and Steel Cover Adapter. The Sprinkler Identification Number (SIN) is VK4621. This is a quick response, standard coverage sprinkler with a maximum working water pressure of 250 PSI (UL), 175 PSI (FM).

    The VK4621 concealed pendent fire sprinkler delivers effective, affordable defense in hazard occupancies up to and including Ordinary Group II. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 200F (93C), drenching the area surrounding a fire to keep it in its place of origin. For concealed application, refer to data sheet for installation instructions with the approved Viking™ cover(s).

    Viking™ Concealed Pendent QR Fire Sprinkler (VK4621) Sprinkler Head Listings and Approvals

    Each Concealed pendent sprinkler is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VNIV), and is FM Approved (Class 2015). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

    Concealed Pendent Sprinkler VK4921 is cULus Listed as standard response for installation in accordance with the latest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated in the Design Criteria chart in the datasheet.

    Viking™ Concealed Pendent Sprinkler VK4621 is FM Approved as a standard response Non-Storage concealed pendent sprinkler as indicated in the FM Approval Guide in the datasheet.

    This concealed pendent head has a maximum working pressure of 250 PSI (17.2 BAR) UL, 175 PSI (12 BAR) FM, and connects to wet piping systems.

    Viking™ QR Concealed Pendent (VK4621) Sprinkler Installation and Other Information

    During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

    This quick response concealed pendent sprinkler is available in three temperatures: 155F (68C), 175F (79C), and 200F (93C). To select your temperature, visit the “Options” section at the top of this product page. Additionally, use the Cover Plate option to select a Cover Plate finish and temperature.

    The VK4621 listed accessories include the approved Viking™ Wrench (part no. 23143), the Viking™ Cover Plate installation tool(s) (part no. 14867, 14412) and the approved Viking™ Cover(s) (part no. 23190, 23174), which are available in a variety of finishes. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

    The VK4621 is a direct replacement to the obsolete VK462.