Grooved Reducing Tee | GemLock® | 2-1/2 in. x 2-1/2 in. x 2 in. | Style 115

SKU:
53-GM-RT-ST-212120
Manufacturer Part Number:
400-210-04580

No reviews yet Write a Review
$71.25

Note: Image may not show actual size. | QRFS


  • Buy 22 - 109 and get 2.5% off
  • Buy 110 or above and get 7.5% off

Frequently Bought Together:

Note: Image may not show actual size. | QRFS
Inc. Tax
Ex. Tax
Overview

GemLock Grooved Reducing Tee

This Grooved x Grooved x Grooved Short Reducing Tee features two 2-1/2 in. connections and one 2 in. connection to be used in grooved pipe systems, including specifically fire sprinkler piping systems, to reduce one pipeline into a smaller diameter pipe, allowing for proper water flow and fast installation. This reducing tee is available in the following sizes:

2-1/2 in. x 2-1/2 in. x 2 in.

3 in. x 3 in. x 2 in., 3 in. x 3 in. x 2-1/2 in.

4 in. x 4 in. x 2 in., 4 in. x 4 in. x 2-1/2 in., 4 in. x 4 in. x 3 in.

5 in. x 5 in. x 2 in., 5 in. x 5 in. x 3 in., 5 in. x 5 in. x 4 in.

6 in. x 6 in. x 2 in., 6 in. x 6 in. x 2-1/2 in., 6 in. x 6 in. x 3 in., 6 in. x 6 in. x 4 in., 6 in. x 6 in. x 5 in.

8 in. x 8 in. x 2 in., 8 in. x 8 in. 3 in., 8 in. x 8 in. x 4 in., 8 in. x 8 in. x 5 in., 8 in. x 8 in. x 6 in.

You can select your preferred size from the “Options” section at the top of this product page. Accessories compatible with this grooved reducing tee include other GemLock grooved fittings and Pipe Joint Lubricant.

GemLock is a leader in the grooved pipe market – their grooved fittings are reliable and faster to install than welding threading, or flanging, resulting in drastically lower installation costs comparatively. GemLock grooved fittings provide a clean, consistent, and strong connection for optimal water flow when used with compatible products. The Victaulic grooved fitting equivalent to this product is the Victaulic Reducer Tee Style 25. Gruvlok fitting equivalent: 7061 Reducer Tee.

GemLock Short Pattern Reducing Tees are made of durable, high-strength ductile iron conforming to ASTM A536, with every lot metallurgically tested for compliance. Pressure Ratings of GemLock Grooved fittings are tested to a maximum operating pressure of 500 PSI*.

*Maximum pressure includes surges and maximum end loads from all internal and external forces, to which a joint could be subject under normal working conditions. This rating provides a nominal safety factor of 1.5 times working pressure based on standard weight steel pipe. Maximum working pressure may be subjected to a one-time field test of 1.5 times the figures indicated.

GemLock Grooved Short Reducing Tee Listings, Approvals, and Other Information

Each grooved reducer tee is made by GemLock, a New York-based manufacturer of grooved fire sprinkler pipe and fittings, HVAC, plumbing and grooved tubing. All GemLock grooved piping system fittings are UL Listed and FM Approved. Refer to installations and groove specifications when assembling any grooved product.

All GemLock Ductile Iron grooved tee fittings conform to ASTM A536 Grade 65-45-12. Allowable pipe end separation is for cut groove pipe for roll groove; figures will be one-half of the values listed at time of initial pressurization.

Certain GemLock product families and all GemLock Grooved fittings 8 in. and larger are only available upon request and are not available for immediate shipping.

Specifications
QRFS SKU:
53-GM-RT-ST-212120
Manufacturer Part Number:
400-210-04580
Manufacturer:
GemLock
Fitting:
Reducing Tee
Style:
Style 115
Size:
2-1/2 in. x 2-1/2 in. x 2 in.
Size Detail:
2-1/2 in. Grooved x 2-1/2 in. Grooved x 2 in. Grooved
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
500 PSI
Finish:
Orange
Length:
6 in. (152.4 mm)
Width:
3 in. (76.2 mm)
Weight:
5.1 lb. (2.31 kg)
Box/Pack Quantity:
22