Reliable™ Model F1Res Residential Pendent (R3516) Fire Sprinkler Head
Sprinkler Identification Number (SIN): R3516
This Pendent sprinkler features a White finish and 155F (68C) temperature.
This Reliable™ Model F1Res Residential Pendent Fire Sprinkler is a standard coverage Residential Pendent fire sprinkler head, activating at 155F (68C) with a 4.9 K-Factor, and is rated for Residential Hazard. Each Pendent head features a heat-sensitive glass bulb assembly, standard 1/2 in. NPT threads, and a brass frame with a brass deflector.
This is a fast response, standard coverage, Pendent sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The R3516 Model F1Res Sprinkler features a low profile and compact design. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.
Reliable™ Model F1Res Fire Sprinkler R3516 Sprinkler Head Listings and Approvals
Each F1Res49 sprinkler is made by Reliable™, a global leader in fire protection manufacturing. When installed properly, this R3516 fire sprinkler head maintains listings and approvals:
cULus Listed Residential Sprinkler
The F1Res Series sprinklers are specially engineered for fast thermal response to meet the requirements of UL 1626. They are intended for installation in accordance with NFPA 13, 13R, and 13D. Refer to the datasheet for listings and approvals in specific temperatures and/or applications.
When using Reliable™ Pendent Sprinkler R3516 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Pendent sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.
Reliable™ (R3516) F1Res49 Pendent Sprinkler Installation and Other Information
The R3516 Pendent Sprinkler is installed exposed or recessed in the Pendent orientation. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ accessories. During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 8-18 ft-lbs (11 – 24 N-m). Refer to the data sheet for additional installation and storage information.
Available finish options include Brass, Chrome, and White.
White Polyester (White) Coating is cULus Listed Corrosion Resistant.
Temperature options include 155F (68C) and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.
The R3516 listed Recessed Escutcheons include the approved Reliable™ Model F1 and Model F2.
The R3516 listed wrenches include the approved Reliable™ Model W2 and Model W4 (Recessed). Add the correct wrench for your R3516 installation.
Available Reliable™ R3516 Pendent Sprinklers & Listed Accessories:
Brass Finish
Reliable™ R3516 Model F1Res Residential Pendent Sprinkler | FR | 4.9K | Brass | 155F | 49BN
Reliable™ R3516 Model F1Res Residential Pendent Sprinkler | FR | 4.9K | Brass | 175F | 49B5N
Chrome Finish
Reliable™ R3516 Model F1Res Residential Pendent Sprinkler | FR | 4.9K | Chrome | 155F | 49CN
Reliable™ R3516 Model F1Res Residential Pendent Sprinkler | FR | 4.9K | Chrome | 175F | 49C5N
White Finish
Reliable™ R3516 Model F1Res Residential Pendent Sprinkler | FR | 4.9K | White | 155F | 49WN
Reliable™ R3516 Model F1Res Residential Pendent Sprinkler | FR | 4.9K | White | 175F | 49W5N
Wrenches:
W-2 Fire Sprinkler Wrench | WW2 | Pendent
W-4 Fire Sprinkler Wrench | WW4 | Recessed Pendent
Recessed Escutcheons:
F1 Recessed | 12-RA-F1 | ¾ in. Adjustment
F2 Recessed | 12-RA-F2 | ½ in. Adjustment