Senju® SS9561 Concealed Pendent Sprinkler | QR | 5.6K | 162F | 002-1001

SKU:
SS9561CP162
Manufacturer Part Number:
002-1001

No reviews yet Write a Review
$20.99

Senju SS9561 162F QR Concealed Pendent 002-1001 Hero Image | QRFS

Senju SS9561 162F QR Concealed Pendent 002-1001 Hero Image | QRFS
Senju SS9561 162F QR Concealed Pendent 002-1001 Side Image | QRFS
Senju SS9561 162F QR Concealed Pendent 002-1001 Deflector Image | QRFS
Senju SS9561 162F QR Concealed Pendent 002-1001 Family Image | QRFS
Senju SS9561 162F QR Concealed Pendent 002-1001 Accessories Image | QRFS
  • Senju RC White Push On 140F 004-0511 Hero | QRFS
  • Senju RC Cherry Chestnut Push On 140F 004-0689 Hero | QRFS
  • Senju RC Ivory Push On 140F 004-0551 Hero | QRFS
  • Senju RC Beige Push On 140F 004-0671 Hero | QRFS
  • Senju RC Yellow Birch Push On 140F  004-0687 Hero | QRFS
  • Senju RC Dark Walnut Push On 140F 004-0690 Hero | QRFS
  • Senju RC Copper Push On 140F 004-0623 Hero | QRFS
  • Senju RC Golden Oak Push On 140F 004-0688 Hero | QRFS
  • Senju RC Douglas Fir Push On 140F 004-0686 Hero | QRFS

  • Buy 50 - 199 and get 3% off
  • Buy 200 or above and get 7% off

Frequently Bought Together:

Senju SS9561 162F QR Concealed Pendent 002-1001 Hero Image | QRFS
Inc. Tax
Ex. Tax
Overview

Senju RC-QR (SS9561) Commercial Flat Concealed Pendent Fire Sprinkler Head

This Senju Model RC-QR Commercial Flat Concealed Pendent fire sprinkler features a fusible link activating at 162F (72C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each concealed pendent sprinkler head features a Copper Alloy Body and Phosphor Bronze Deflector. This sprinkler was designed to be covered by a Senju RC cover plate, allowing for optimal aesthetics and proper function within commercial settings. The manufacturer part number is 002-1001 and the Sprinkler Identification Number (SIN) is SS9561.

The Model RC-QR Commercial Sprinkler delivers decorative, affordable defense against fire and is designed for use in commercial fire sprinkler systems. Using a heat-activated fusible metal assembly, this automatic fire sprinkler opens when ambient temperatures reach 162F (72C), drenching the area surrounding a fire to keep it in its place of origin.

Senju RC-QR (SS9561) Commercial Flat Concealed Pendent Sprinkler Head Listings and Approvals

Each RC-QR sprinkler is made by Senju, Japan's largest manufacturer of fire-suppression products. This flat concealed fire sprinkler head maintains UL Listing as Quick Response and is FM Approved as Standard Response.

The SS9561 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial settings. This concealed pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL Listed and FM Approved and connects to wet pipe sprinkler systems.

Senju RC-QR (SS9561) Commercial Concealed Sprinkler Head Pendent Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This concealed sprinkler head is available in two temperatures: 162F (72C) and 205F (96C) and must be paired with a Senju RC Cover Plate. These cover plates come in a variety of temperatures: 140F (60C) and 162F (72); shapes: Round and Square (white only); and finishes: White, Ivory, Nickel, Beige, Brown, Black, Copper, and multiple Wood Grain options. To choose your cover plate, find the “Options” section at the top of this product page.

Along with the required Cover Plate, SS9561 listed accessories include the NR-H socket wrench, manufacturer part number (90000-003-0400), the RC Cover Plate Installation Tool, manufacturer part number (90000-003-1000), and the RC Cap Removal tool, manufacturer part number (90000-003-3000). This sprinkler head is commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Specifications
QRFS SKU:
SS9561CP162
Manufacturer Part Number:
002-1001
Manufacturer:
Senju
SIN:
SS9561
Model:
RC-QR
Head Type:
Concealed Pendent
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
162F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Copper Alloy Body, Phosphor Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI
Length:
2.06 in. (52.32 mm)
Width:
2.06 in. (52.32 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.25 lb. (0.11 kg)
Box/Pack Quantity:
100
Reviews
No reviews yet

Customers Also Viewed

Senju Cap Removal Tool | RC Heads Senju Cap Removal Tool | RC Heads

Senju Cap Removal Tool | RC Heads

SKU : SCP2

$21.99
Remove Senju fire sprinklers' protective caps quickly with Senju Fire Sprinkler Cap Removal Tool for RC Heads. Available in ivory-finished nylon, this cap puller allows sprinkler fitters to walk...