Solo 200 | Remove Smoke Detectors and CO Sensors | 2 1/2″ – 4 1/2″ Diameter

SKU
SOLO200
The Solo 200 Detector Removal Tool can grab and remove smoke alarms, carbon monoxide sensors, and other detectors in hard-to-reach areas. This lightweight (2.4 lb.) tool pairs with Solo-brand access poles (sold separately) to grasp devices from 10 to 30 feet away. Designed for detectors of roughly 2 1/2″ to 4 1/2″ in diameter (65 mm to 110 mm).
$469.99
SKU Construction Detector Diameter
SOLO200 Lightweight Telescopic Attachment 65 mm to 110 mm (Roughly 2 1/2″ to 4 1/2″)
Compatible Extension Poles Solo Model Availability
Solo 100, Solo 101, Solo 108 Solo 200 Usually Ships Within 48 Hours

Solo 200 Smoke Detectors and CO Sensor Removal Tool (2 1/2″ – 4 1/2″ Diameter)

The Solo 200 can attach or remove smoke alarms, carbon monoxide sensors, and other detectors in hard-to-reach areas. This lightweight (2.4 lb.) tool pairs with Solo-brand access poles (sold separately) to grasp devices from 10 to 30 feet away.

Designed for detectors of roughly 2 1/2″ to 4 1/2″ in diameter (65 mm to 100 mm), this tool features a universal design with three color-coded sizes. The pivoting head makes this tool able to grasp detectors on even on sloped or angled ceilings.

Is this a standalone tool?

No. The Solo 200 removes smoke detectors and CO sensors using a Solo-brand extension pole. Depending on the attachments used, this tool can grasp detectors from distances of 14 to 30 feet. Available extension poles include:

These telescopic, no-climb extension poles provide convenience and safety, eliminating the need for ladders or climbing equipment.

For more options, consider Solo’s line of access and testing equipment, including:

How do I use the Solo 200?

The Solo 200 slides into the end of a Solo 100, Solo 101, or Solo 108 extension pole. To attach it, follow these steps:

  • To size the Solo 200 for the electronic device you plan to grip, pull and twist the color-coded grips at the end of the tool.
  • If you plan to use the device at an angle, insert the Solo 200 into the extension pole and guide the lower spring-loaded button into the locking hole.
  • If you plan to hold the pole vertically, insert the Solo 200 into the extension pole and guide the upper spring-loaded button into the locking hole.

To remove an existing detector:

  • Use the extension pole to guide the Solo 200 to the detector.
  • Place the detector between the three color-coded grips and push up.
  • Twist the pole (counterclockwise, typically) to uncouple the detector from the mounting ring.
  • When the detector is free, pull down to remove it from the wall or ceiling.

To attach a new detector:

  • Place the device between the Solo 200’s three color-coded grips.
  • Guide the detector to the mounting ring using the extension pole.
  • Twist (clockwise, usually) to lock the detector in the ring.
  • Pull down to free the Solo 200 from the detector.

Remember to:

  • Stand with one foot slightly in front of the other to reduce strain and improve balance.
  • Share the load with others—and take regular breaks.
  • Occasionally switch the position of the pole, holding it either on the right-hand or the left-hand side of the body.
  • Hold the pole perpendicular to the ground and stand directly under the top of the pole.
  • If this product must be held at an angle, stand no more than 5 feet away from a point directly beneath the detector.

Documentation

View the manual for the Solo 200.