Safe Signal™ | Supervisory Switch For OS&Y Valves | OSY2 Tamper Switch

SKU:
28-SF-SVS-OSY2
Manufacturer Part Number:
OSY2
$205.29

Select Variation

  • Buy 5 - 24 and get 5% off
  • Buy 25 or above and get 10% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
28-SF-SVS-OSY2
Manufacturer Part Number:
OSY2
Manufacturer:
Safe Signal™
Product Type:
Supervisory Switch
Model:
OSY2
Operating Temperature Range:
32F-120F
Pipe/Part Compatability:
OS&Y Valves
Maximum Stem Extension:
25/8 in.
Switch Contact Rating:
10A 125/250VAC
Enclosure Rating:
Indoor/Outdoor
Conduit Entrance:
1/2 in. (1)
UL Listed:
Yes
FM Approved:
Yes
Length:
3.25 in. (82.55 mm)
Width:
3.5 in. (88.9 mm)
Height:
5.75 in. (146.05 mm)
Weight:
2.8 lb. (1.27 kg)
Sourced Location:
USA

Safe Signal™ | Supervisory Switch For OS&Y Valves | OSY2 Tamper Switch | QRFS™ | Hero Image

Best Seller
Safe Signal™ | Supervisory Switch For OS&Y Valves | OSY2 Tamper Switch | QRFS™ | Hero Image
Safe Signal™ | Supervisory Switch For OS&Y Valves | OSY2 Tamper Switch | QRFS™ | Side Image
Safe Signal™ | Supervisory Switch For OS&Y Valves | OSY2 Tamper Switch | QRFS™ | Label Image
Overview

Safe Signal™ Supervisory Switch OSY2 Tamper Switch for OS&Y Valves

This Safe Signal™ OSY2 Supervisory Switch, also known as a Tamper Switch, identifies tampering in a fire protection system by sending an alarm signal to a nearby alarm or fire alarm control panel when an Outside Screw and Yoke (OS&Y) valve has been closed or tampered with. This tamper switch also features 100% synchronization, meaning it will activate both the alarm panel and local bell simultaneously, if needed.

This device features a user-friendly mounting bracket that will fit newer valve yokes, and an adjustable shaft to permit mounting to most sizes of OS&Y valves, from 1-12 in. Its right-angled construction and wide bracket provide as much clearance as possible for troublesome components. Furthermore, removing this switch’s gate valve bracket allows the unit to monitor side-bracket style pressure reducing valves.

This Supervisory Switch features a rugged housing and is UL Listed to operate at a temperature range of 32-120F. It has a maximum stem extension of 25/8 in. and is NEMA 3R & UL Listed for use indoors and outdoors when the actuator is mounted vertically. It has two sets of Single Pole Double Throw (SPDT) switches that have a contact rating of 10A 125/250VAC; 2.5A 6/12/24VDC. Accommodates up to 12 AWG wire & equipped with tamper-resistant cover screws to prevent unauthorized entry.

Why is it important to keep my OS&Y Valve open?

Outside Screw and Yoke (OS&Y) valves are vital components of fire protection systems – they control the flow of water and other extinguishing agents during fire emergencies. Properly functioning OS&Y valves play a crucial role in ensuring the effectiveness of fire suppression efforts and safeguarding lives and property.

In the event of a fire, a fire sprinkler system relies on a constant water supply. If the OS&Y valve is closed, water flow to the system will be obstructed, and the sprinklers will not activate as intended, delaying the response to the fire, and potentially allowing it to spread. Keeping this valve open is also important for long-term care and maintenance – a closed OS&Y valve can lead to loss of pressure in the system over time due to trapped air or minor leaks. By keeping the valve open, the fire protection system remains pressurized and ready for immediate activation when needed. A supervisory switch can help ensure that these valves are in proper working condition. Furthermore, many building codes and fire safety regulations require OS&Y valves in fire protection systems, including sprinkler systems, to be continuously operational and compliant.

Reviews
No reviews yet
Product Alternatives