Safe Signal™ Alarm Pressure Switch | EPS40-2 High/Low Pressure w/ 2 SPDT | 10-100 PSI

SKU:
28-SF-EPS40-2
Manufacturer Part Number:
EPS40-2
$227.07

Select Variation

  • Buy 5 - 24 and get 5% off
  • Buy 25 or above and get 10% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
28-SF-EPS40-2
Manufacturer Part Number:
EPS40-2
Manufacturer:
Safe Signal™
Product Type:
Alarm Pressure Switch
Model:
EPS40-2 High/Low Pressure
Operating Temperature Range:
-40F-160F
Maximum Pressure Rating:
300 PSI
Adjustment Pressure Range:
10-100 PSI
Differential:
~3 (10 PSI), 6 (100 PSI)
Factory Setting:
> 50 PSI, < 30 PSI
Switches:
2 SPDT
Switch Contact Rating:
10A 125/250VAC, 2.5A 6/12/24VDC
Size:
1/2 in.
Size Detail:
1/2 in. NPT
Enclosure Rating:
Indoor/Outdoor
Conduit Entrance:
1/2 in. (2)
UL Listed:
Yes
FM Approved:
Yes
Length:
4.25 in. (107.95 mm)
Width:
3.33 in. (84.58 mm)
Height:
5.15 in. (130.81 mm)
Weight:
1.2 lb. (0.54 kg)
Sourced Location:
USA

Safe Signal™ Alarm Pressure Switch | EPS40-2 High/Low Pressure w/ 2 SPDT | 10-100 PSI | QRFS™ | Hero

Safe Signal™ Alarm Pressure Switch | EPS40-2 High/Low Pressure w/ 2 SPDT | 10-100 PSI | QRFS™ | Hero
Safe Signal™ Alarm Pressure Switch | EPS40-2 High/Low Pressure w/ 2 SPDT | 10-100 PSI | QRFS™ | Side
Safe Signal™ Alarm Pressure Switch | EPS40-2 High/Low Pressure w/ 2 SPDT | 10-100 PSI | QRFS™ | Bottom
Overview

Safe Signal™ Alarm Pressure Switch EPS40

These Safe Signal™ EPS40 Alarm Pressure Switches, also known simply as Pressure Switches, are devices used to monitor and detect the pressure changes in dry pipe systems or pressure tanks and water pressure supplies of automatic water control valves. These pressure switches are typically installed in-line with a bleeder valve and wired to a supervisory circuit of the fire alarm control panel. These components are typically between the system’s check valve and the dry pipe valve.

Proper system pressure is essential for the efficient operation of the sprinklers during a fire event. The primary function of these products is to monitor the pressure in the system and activate an alarm signal if the pressure falls below or rises above the predetermined setpoint. The EPS40 features field adjustable pressure sensitivity to provide an alarm response between 10-100 PSI.

These NEMA 4 Rated Alarm Pressure Switches are designed for indoor and outdoor use. They have an operating temperature range of -40-160F, a maximum operating pressure of 300 PSI, and a differential of approximately 3 PSI at 10 PSI, or 6 PSI at 100 PSI. They have two 1/2 in. conduit entrances, a contact rating of 10A 125/250VAC; 2.5A 6/12/24VDC.

Safe Signal™ Alarm Pressure Switch EPS40 Options & Other Information

The EPS40 Pressure Switch is available in two options: The EPS40-1 Low Pressure Switch, or the EPS40-2 High/Low Pressure Switch.

The EPS40-1 features one Single Pole Double Throw (SPDT) switches and is factory set to operate at a decreasing pressure at 30 PSI.

The EPS40-2 features two Single Pole Double Throw (SPDT) switches and is factory set to operate at a decreasing pressure at 30 PSI and an increasing pressure at 50 PSI.

Both Models are UL Listed and FM Approved.

Reviews
No reviews yet
Product Alternatives