Safe Signal™ Waterflow Detector | 5 in. | 450 PSI Flow Switch

SKU:
28-SF-WFD-25
Manufacturer Part Number:
WFD50N
$297.76
Data Sheet Product Data Sheet

Select Variation

  • Buy 5 - 24 and get 5% off
  • Buy 25 or above and get 10% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
28-SF-WFD-25
Manufacturer Part Number:
WFD50N
Manufacturer:
Safe Signal™
Product Type:
Waterflow Detector
Model:
WFDN
Operating Temperature Range:
32F-150F
Pipe/Part Compatability:
Steel, Schedule 10-40
Maximum Pressure Rating:
450 PSI
Switch Contact Rating:
10A 125/250VAC
Size:
5 in.
Size Detail:
5 in. Pipe Size
Hole Size:
2 in.
Maximum Surge:
18 FPS
Triggering Threshold (Flow Rate):
4-10 GPM
Enclosure Rating:
Indoor/Outdoor
Installation:
Vertical or Horizontal
Conduit Entrance:
1/2 in. (2)
UL Listed:
Yes
FM Approved:
Yes
Length:
3.5 in. (88.9 mm)
Width:
7.5 in. (190.5 mm)
Height:
10 in. (254 mm)
Weight:
4.9 lb. (2.22 kg)
Sourced Location:
USA

Safe Signal™ Waterflow Detector | 5 in. | 450 PSI Flow Switch | QRFS™ | Hero Image

Safe Signal™ Waterflow Detector | 5 in. | 450 PSI Flow Switch | QRFS™ | Hero Image
Safe Signal™ Waterflow Detector | 5 in. | 450 PSI Flow Switch | QRFS™ | Side Image
Safe Signal™ Waterflow Detector | 5 in. | 450 PSI Flow Switch | QRFS™ | Label Image
Safe Signal™ Waterflow Detector | 5 in. | 450 PSI Flow Switch | QRFS™ | Other Side Image
Overview

Safe Signal™ Waterflow Detector Flow Switches

These Safe Signal™ Waterflow Detectors, also known as Flow Switches, Water Flow Switches, or Sprinkler Flow Switches, are devices used in fire protection pipe systems to monitor and detect the flow of water. These detectors are installed in pipe systems so water will flow past it, activating the switch to signal to a control panel or alarm system that the fire sprinkler system may be activating. In some cases, false alarms happen, and this product features a timer dial that allows for a set delayed reaction to ensure that water is steadily flowing through the switch.

Along with signaling for water-flow, these detectors verify that water is flowing when it is supposed to, and if the switch doesn’t activate when a known fire event is taking place, it indicates a potential issue in the system or a closed valve. These flow switches are critical in fire protection systems, and many building codes and regulations require their installation.

These Safe Signal™ detectors consist of a rugged, NEMA 4-rated enclosure that is more damage resistant than other designs. Featuring a corrosion resistant lightweight cover with tamper-resistant cover screws, they have a sealed retard mechanism immune to dust and other contaminants. They are designed for indoor and outdoor use and can be installed vertically or horizontally. They have an operating temperature range of 32-150F and are UL Listed and FM Approved for installation in Steel Schedule 7-40 piping (2-4 in.) or Steel Schedule 10-40 pipe (5-8 in.). They have a triggering threshold (flow rate) of 4-10 Gallons Per Minute (GPM).

Safe Signal™ Waterflow Detector Sprinkler System Flow Switch Sizes, Other Information

These Waterflow Detectors are available in seven different sizes, each of which are compatible with specific pipe sizes:

2 in., 2-1/2 in., 3 in., 4 in., 5 in., 6 in., 8 in.

These switches have two 1/2 in. conduit entrances, a contact rating of 10A 125/250VAC; 2.5A 6/12/24VDC, and a maximum surge of 18 Feet Per Second (FPS). Every size of the Safe Signal™ Waterflow Detectors are UL Listed and FM Approved.

Reviews
No reviews yet
Product Alternatives