Flanged Swing Check Valve | 2 in. NPT | Ductile Iron | MECH™ | H44X220

SKU:
73-VN-SWNG-FF-200000
Manufacturer Part Number:
H44X220
$257.50

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
73-VN-SWNG-FF-200000
Manufacturer Part Number:
H44X220
Manufacturer:
MECH™
Valve Type:
Check Valve
Connection Type:
Flanged
Body Material:
ASTM A536, 65-45-12 Ductile Iron
Size:
2 in.
Size Detail:
2 in. NPT Valve
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
300 PSI
Rated Working Temperature Range:
32F to 176F (0C to 80C)
Finish:
Red
Weight:
25 lbs (11.34 kg.)

Flanged Swing Check Valve | 2 in. NPT | Ductile Iron | MECH™ | H44X220

Overview

MECH™ H44X2 Flanged Resilient Swing Check Valve

The MECH™ Check Valve is a flanged swing check valve intended for fire sprinkler system service, where maintaining one-way flow helps protect overall system reliability. In fire protection piping, reverse flow can contribute to unwanted drainage, unstable pressures, and added stress on connected equipment and system components. A swing check valve uses a hinged clapper that opens with forward flow and closes when flow stops or begins to reverse, helping limit backflow and supporting steady system conditions during normal operation, inspection activity, and testing. This valve is manufactured with a durable ASTM A536, 65-45-12 Ductile Iron body for strength and long service life in demanding water-service environments, and it is supplied with a high-visibility Red finish to support identification in risers, valve assemblies, and mechanical room installations.

This valve uses a Flanged connection type consistent with common bolted-joint layouts used in many fire protection applications. It is rated for a maximum working water pressure of 300 PSI and is intended to operate within a rated working temperature range of 32F to 176F (0C to 80C), aligning with typical above-freezing fire protection water supply conditions. The H44X2 resilient seated swing check valve design is commonly specified where a dependable, automatic non-return function is needed without manual operation, helping support system integrity during changing demand while maintaining the intended direction of flow. This valve is UL Listed and FM Approved.

The valve family is offered across multiple system sizes while maintaining the same core attributes—ductile iron construction, flanged ends, a 300 PSI working-pressure rating, a 32F to 176F (0C to 80C) temperature range, and a Red exterior finish—supporting consistent specification across a range of fire protection system layouts. It is supplied by MECH™ and is categorized as a Check Valve for fire protection water service applications requiring dependable backflow prevention through swing-check operation.

This valve is also available in the following sizes: 2 in. NPT Valve; 2-1/2 in. NPT Valve; 3 in. NPT Valve; 4 in. NPT Valve; 6 in. NPT Valve; 8 in. NPT Valve; 10 in. NPT Valve; 12 in. NPT Valve.

Reviews
No reviews yet
Product Alternatives