Viking® Mirage Cleanroom Cover Plate | Stainless | 135F | 3-5/16 in. OD | 23183A/CR

SKU:
11-VK-23183-SS135-CR
Manufacturer Part Number:
23183A/CR

No reviews yet Write a Review
MSRP: $117.50
$102.25
You save $15.25

Viking® Mirage Cleanroom Cover Plate | Stainless Steel | 135F | QRFS | Hero

Play Button

Frequently Bought Together:

Viking® Mirage Cleanroom Cover Plate | Stainless Steel | 135F | QRFS | Hero
Inc. Tax
Ex. Tax
Overview

Viking Mirage Stainless Steel Cleanroom Fire Sprinkler Cover Plate

Viking Mirage Cleanroom Stainless Steel Fire Sprinkler Cover Plate with 135F (57C) activation temperature. This fire sprinkler cover works with certain Viking concealed fire sprinklers.  The Mirage Cleanroom cover facilitates timely activation of these Viking concealed fire sprinkler heads with a temperature rating of 135F (57C). This cover plate is intended for use in cleanroom environments – the silicone cover gasket is pre-assembled with the concealed cover for an acceptable sprinkler seal for us in a cleanroom or clean zone. The outer diameter of this cover is 3-5/16 in. This Viking cover plate is available with a 1/2 in. adjustment.

The Viking Mirage Stainless Cleanroom cover plate is a flat concealed cover plate used with compatible sprinklers.  It provides a thread-on connection into the sprinklers cup. This stainless steel cover plate can be used with standard brass models, however, combining them with ENT plated concealed sprinklers creates an enhanced assembly providing and even higher level of overall resistance to corrosion. This assembly is well-suited for many applications where corrosion is a possible concern, such as food and pharmaceutical processing, food service areas, industrial wash down areas, parking garages, saunas, locker rooms, and sprinkler system installations near the ocean.

Viking Mirage Stainless Cleanroom Cover Plate Sprinkler Head Compatibility and Listings

This Sprinkler Head Cover Plate from Viking may be listed by UL, FM, and/or other organizations depending on the sprinkler it’s being used with. It meets the requirements of a sprinkler assembly per NFPA 13, where approved by the local Authority Having Jurisdiction. It installs by simply threading the cover into the sprinkler’s frame, and can be adjusted up to 1/2 in. The recommended hole diameter when installing sprinkler heads using this cover is 2-1/4 in.

To remove your existing cover plate, gently twist the cover to the left while applying downward pressure by pulling gently as you turn.

When this fire sprinkler cover plate reaches its specified temperature of 135F (57C) the solder holding the plate's decorative exterior on the frame melts, and the two separate. For many cover plates, the rated temperature is at least 20F (6.7C) cooler than the sprinkler head's activation temperature, which ensures that the cover plate detaches early enough to allow the sprinkler to activate on time. However, each manufacturer's product line varies slightly, and cover plate temperatures may be closer to or further away from the fire sprinkler's activation temperature. Use only the cover plate approved by the manufacturer for your specific sprinkler.

Viking Mirage Stainless Cleanroom Cover Plate Finishes, Temperatures, and Listed Accessories

This Viking Mirage fire sprinkler cover plate is available in corrosion resistant stainless steel. It is available at a temperature of 135F (57C). Find all related products in the Frequently Bought Together section above.

Viking is a leader in the fire protection manufacturing industry, with a variety of sprinkler heads, escutcheons, and cover plates.

This Sprinkler Cover Plate fits the following Viking concealed sprinkler heads:

  • VK462
  • VK4621
Specifications
QRFS SKU:
11-VK-23183-SS135-CR
Manufacturer Part Number:
23183A/CR
Manufacturer:
Viking
Model:
Mirage Cleanroom
Installation Type:
Thread On
Adjustment:
1/2 in.
Outer Diameter:
3-5/16 in.
Inner Diameter:
1-31/32 in.
Finish:
Stainless Steel
Finish Detail:
Stainless
Temperature:
135F
Corrosion Resistant:
Yes
UL Listed:
Yes
FM Approved:
No
Length:
3.31 in. (84.07 mm)
Width:
3.31 in. (84.07 mm)
fmt_variance:
Cleanroom
Available Box/Pack Quantity:
50