Reliable™ Model F156 Standard Response Horizontal Sidewall (RA1335) Fire Sprinkler Head
Sprinkler Identification Number (SIN): RA1335
This horizontal sidewall sprinkler features a White finish and 175F (79C) temperature.
(1) 286°F (141°C) and higher temperature rated sprinkler not listed for recessed use.
(2) cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed.
(3) Not suitable for recessed horizontal sidewall installations.
(4) FM Approved for Light Hazard ONLY.
This Reliable™ Model F1-56 Horizontal sidewall Fire Sprinkler is a standard coverage, horizontal sidewall fire sprinkler head, activating at 175F (79C) with a 5.6 K-Factor, and is rated for Light and Ordinary Hazard occupancies. Each horizontal sidewall head features a heat-sensitive glass bulb assembly, standard 1/2 in. NPT threads, and a brass frame with a brass/bronze deflector.
This is a standard response, standard coverage, horizontal sidewall sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The RA1335 Model F156 Sprinkler features a durable and low-profile appearance. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), drenching the area surrounding a fire to keep it in its place of origin.
The RA1335 is installed exposed, surface mounted, or recessed. Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. Refer to the manufacturer data sheet for installation instructions with the approved Reliable™ accessories.
Reliable™ Model F156 Fire Sprinkler RA1335 Sprinkler Head Listings and Approvals
Each F156 sprinkler is made by Reliable™, a global leader in fire protection manufacturing for over 100 years. When installed properly, this RA1335 fire sprinkler head maintains listings and approvals: cULus Listed, FM Approved Refer to the datasheet for listings and approvals in specific temperatures and/or applications.
When using Reliable™ Horizontal sidewall Sprinkler RA1335 for systems designed to NFPA 13, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This horizontal sidewall sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.
Reliable™ F156 (RA1335) Horizontal Sidewall Sprinkler Installation and Other Information
During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.
Available finishes include Brass, Chrome, and White. White Polyester Finish (White is UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), 286F (141C), 360F (182C), and 500F (260C). Finish and temperature combinations available in the “Options” section at the top of this product page.
The RA1335 listed wrenches include the approved Reliable™ Model W2 (horizontal), Model W4 (recessed), Model W14 (New frame with guard installed), and Model W13 (Legacy frame with guard installed). Add the correct wrench for your RA1335 installation. Sprinklers with Legacy frames require an alternative W13 wrench for proper installation.
Other listed accessories include Reliable™ sprinkler head guards and water shields, listed below and available at the top of this page. Prevent accidental activation or damage to your RA1335 sprinkler by installing the appropriate head guard and ensure the timely activation of your intermediate horizontal sidewall sprinkler head by installing an appropriate water shield. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.
Available Reliable™ RA1335 Horizontal Sidewall Sprinklers:
Brass:
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Brass | 135F | F56U0BN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Brass | 155F | F56U1BN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Brass | 175F | F56U5BN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Brass | 200F | F56U2BN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Brass | 286F | F56U3BN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Brass | 360F | F56U6BN
Chrome:
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Chrome | 135F | F56U0CN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Chrome | 155F | F56U1CN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Chrome | 175F | F56U5CN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Chrome | 200F | F56U2CN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Chrome | 286F | F56U3CN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | Chrome | 360F | F56U6CN
White:
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | White | 135F | F56U0WN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | White | 155F | F56U1WN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | White | 175F | F56U5WN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | White | 200F | F56U2WN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | White | 286F | F56U3WN
RA1335 Horizontal Sidewall Sprinkler | SR | 5.6K | White | 360F | F56U6WN
Wrench:
W-2 Fire Sprinkler Wrench | WW2
W-4 Fire Sprinkler Wrench | WW4
W-14 Fire Sprinkler Wrench | W14 | New frame with guard installed
W-13 Fire Sprinkler Wrench | W13 | Legacy frame with guard installed
Recessed Escutcheons:
Model F1 Escutcheon (cULus, FM)
Model F2 Escutcheon (cULus, FM)
Model FP Escutcheon (cULus)
Guards & Shields (New Frames):
F-4 Guard (FM)
F-7 Guard/Shield Kit (cULus)
Guards & Shields (Legacy Frames):
F-4 Guard (FM)
F-7 Guard/Shield Kit (cULus)