Reliable™ RA5422 Upright Sprinkler | QR | 8.0K | Brass | 212F | KFR80U2B

SKU:
RA5422BR212
Manufacturer Part Number:
KFR80U2B
$21.51
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
RA5422BR212
Manufacturer Part Number:
KFR80U2B
Manufacturer:
Reliable™
SIN:
RA5422
Model:
KFR80
Head Type:
Upright
Finish:
Brass
Finish Detail:
Bronze
Size:
3/4 in.
Size Detail:
3/4 in. NPT Sprinkler
K Factor:
8.0K
Response Type:
Quick Response (QR)
Temperature:
212F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
cULus Listed, VdS, CE, UKCA
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
2.375 in. (60.325 mm)
Width:
1.375 in. (34.925 mm)
Height:
2.375 in. (60.325 mm)
Weight:
0.2 lbs. (0.09 kg)
System Type:
Wet

Reliable™ RA5422 Upright Sprinkler | QR | 8.0K | Brass | 212F | KFR80U2B

Reliable™ RA5422 Upright Sprinkler | QR | 8.0K | Brass | 212F | KFR80U2B
Reliable™ RA5422 Upright Sprinkler | QR | 8.0K | Brass | 212F | KFR80U2B
Reliable™ RA5422 Upright Sprinkler | QR | 8.0K | Brass | 212F | KFR80U2B
Reliable™ RA5422 Upright Sprinkler | QR | 8.0K | Brass | 212F | KFR80U2B
Overview

Reliable™ RA5422 Quick Response (QR) Upright Sprinkler | 8.0K | Brass | 212°F | Part No. KFR80U2B

The Reliable™ KFR80 Upright fire sprinkler (SIN RA5422) is a quick response, standard spray sprinkler designed for dependable fire protection in approved light and ordinary hazard applications. Part number KFR80U2B uses a nominal 8.0 K-factor (115 metric) and a 212°F (100°C) intermediate temperature-rated fusible link operating element, paired with a brass finish for a clean, traditional metallic appearance in exposed installations.

In operation, the sprinkler’s heat-responsive fusible link releases at its rated temperature, allowing water to discharge through the upright body and strike the deflector to create a uniform standard spray pattern intended to help control fire growth. The sprinkler installs with a 3/4" NPT connection (ISO 7-1 R3/4 optional) and is built with durable components for long-term reliability in wet-pipe systems when installed and maintained to applicable codes and the manufacturer’s instructions.

Listings and approvals are provided per the manufacturer’s published literature and commonly include cULus listing and FM approval, with additional regional approvals available depending on configuration and jurisdiction.

Key performance details include the 8.0 K-factor, upright orientation, quick response standard spray discharge, a 212°F temperature rating, and system pressure limits that follow the sprinkler’s applicable listings and approvals.

This series is also offered in multiple finishes and temperature ratings to match job requirements, including brass, bronze, chrome plated, and white polyester, with temperature options that include 165°F and 212°F.

For best results, install using the manufacturer-recommended sprinkler wrench and avoid over-tightening, impact, or contamination of the operating element. Do not install any sprinkler that appears damaged or has been field-painted, and maintain the system in accordance with NFPA 25 and the authority having jurisdiction.

Reviews
No reviews yet
Product Alternatives