Air/Water Pressure Gauge | Dry | 3-1/2 in. | 0-300 PSI

SKU:
44-LN-PSG-040
Manufacturer Part Number:
100-325-00040
$18.99
  • Buy 10 - 49 and get 5% off
  • Buy 50 or above and get 10% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
44-LN-PSG-040
Manufacturer Part Number:
100-325-00040
Manufacturer:
Lansdale™
Use:
Air & Water Based Systems
Application:
Air/Water Pressure
Gauge Fill:
Dry
Gauge Range Options:
No
Gauge Range(s):
0-300 PSI
Units of Measurement:
PSI, kPa
Case Material:
Stainless Steel
Other Material:
Glass Window, Brass Dial
Size:
3-1/2 in.
Size Detail:
3-1/2 in. Gauge
Connection:
1/4 in. NPT Connection
Outer Diameter:
3-31/32 in.
NIST Certificate Available:
No
Accuracy:
+/- 3/2/3%
UL Listed:
Yes
FM Approved:
Yes
Length:
4 in. (101.6 mm)
Width:
1.33 in. (33.78 mm)
Height:
4.5 in. (114.3 mm)
Weight:
0.69 lb. (0.31 kg)

Air/Water Pressure Gauge | Dry | 3-1/2 in. | 0-300 PSI | QRFS™ | Hero

Air/Water Pressure Gauge | Dry | 3-1/2 in. | 0-300 PSI | QRFS™ | Hero
Air/Water Pressure Gauge | Dry | 3-1/2 in. | 0-300 PSI | QRFS™ | Dial
Air/Water Pressure Gauge | Dry | 3-1/2 in. | 0-300 PSI | QRFS™ | Back
Play Button
Overview

Dry 3-1/2 in. Air/Water Pressure Gauge

This Dry Dial 3-1/2 in. Air/Water Pressure Gauge is designed to deliver +/- 3/2/3% accurate pressure ratings in a range of 0-300 PSI in wet or dry-pipe fire sprinkler system and other air/water-based systems. This gauge has a 1/4 in. NPT connection that threads quickly testing equipment. This Gauge is UL Listed and FM Approved.

Why Do I Need a Water Pressure Gauge?

Water pressure gauges are essential components for monitoring the water supply and ensuring that adequate pressure is maintained to effectively operate the sprinkler system.

During normal operation, the water gauge provides a visual indication of the water pressure in the system. It allows the building owners, maintenance personnel, or fire safety professionals to verify that the pressure is within the desired range for proper sprinkler system functionality. Adequate pressure ensures that water will be discharged from the sprinkler heads when activated, effectively suppressing, or controlling a fire.

Regular monitoring of the water gauge is important to identify any abnormal fluctuations or drops in pressure, which could indicate potential issues such as leaks, valve malfunctions, or water supply problems. If the water gauge shows an abnormal reading, it should be investigated and addressed promptly to maintain the reliability of the fire sprinkler system.

Why Do I Need an Air Pressure Gauge?

In a dry pipe fire sprinkler system, air gauges play a crucial role in monitoring the air pressure within the system. Unlike wet pipe systems where water is constantly present in the pipes, dry pipe systems contain pressurized air that holds back the water until a sprinkler head is activated. Air gauges are used to measure and display the air pressure within the system.

During normal operation, the air gauge provides a visual indication of the pressure in the system. It allows the building owners, maintenance personnel, or fire safety professionals to verify that the pressure is within the desired range for proper sprinkler system functionality. Adequate pressure ensures that water will be discharged from the sprinkler heads when activated, effectively suppressing, or controlling a fire.

Regular monitoring of the air gauge is important to identify any abnormal fluctuations or drops in pressure, which could indicate potential issues such as leaks and valve malfunctions. Conversely, if the air pressure is too high, it may trigger a false activation of the sprinkler heads or put unnecessary strain on the system. If the air gauge shows an abnormal reading, it should be investigated and addressed promptly to maintain the reliability of the fire sprinkler system.

Reviews
1 review |
1 review
  • 5

    Ok

    Posted by Sławek on Mar 27th 2025

    Ok

Product Alternatives