Tyco™ TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 280F | 53-106-1-280

SKU:
TY4811BR280
Manufacturer Part Number:
53-106-1-280
$69.07
  • Fire Sprinkler Wrench | Tyco™ W-Type 9 | Standard | 56-000-1-849 | QRFS™ | Hero

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
TY4811BR280
Manufacturer Part Number:
53-106-1-280
Manufacturer:
Tyco™
SIN:
TY4811
Model:
TY-L
Head Type:
Upright
Finish:
Brass
Finish Detail:
Natural Brass
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
8.0K
Response Type:
Standard Response (SR)
Temperature:
280F
Heat Element:
Fusible Link
Coverage:
Standard Coverage
Material:
Brass Frame, Bronze Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Occupancy Type:
Light, Ordinary, Extra Hazard
Maximum Working Water Pressure:
175 PSI
Length:
1.57 in. (39.878 mm)
Width:
1.57 in. (39.878 mm)
Height:
2.63 in. (66.802 mm)
Weight:
0.3 lbs. (0.14 kg)

Tyco™ TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 280F | 53-106-1-280 | QRFS™ | Hero

Tyco™ TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 280F | 53-106-1-280 | QRFS™ | Hero
Tyco™ TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 280F | 53-106-1-280 | QRFS™ | Front
Tyco™ TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 280F | 53-106-1-280 | QRFS™ | Deflector
Overview

Tyco™ Model TY-L Upright Fire Sprinkler Head

Sprinkler Identification Number (SIN): TY4811

This Upright sprinkler features a Brass finish and a 280°F (137°C) temperature.

This Tyco™ Model TY-L Upright Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 280°F (137°C) with a 8.0 K-Factor, and is rated for light, ordinary hazard occupancies. Each Upright head features a heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a Brass frame with Bronze deflector.

This is a standard response, standard coverage, Upright sprinkler with a maximum working water pressure of 175 PSI. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, effectively containing the spread of fire.

The TY4811 is installed in the Upright position.

Tyco™ Upright Fire Sprinkler (TY4811) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Tyco™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this TY4811 maintains the following listings and approvals: UL, C-UL, FM
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

The Tyco™ Upright Sprinkler TY4811 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet pipe fire protection systems.

Tyco™ TY4811 Automatic Fire Sprinkler Installation and Accessories

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.

Listed TY4811 Accessories include:

Sprinkler Wrenches:

  • W-Type 9 Standard Sprinkler Wrench

Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Available Sprinklers:
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 165F | 53-106-1-165
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 212F | 53-106-1-212
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 280F | 53-106-1-280

Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Chrome | 165F | 53-106-7-165
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Chrome | 212F | 53-106-7-212
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Chrome | 280F | 53-106-7-280