Tyco™ Model TY-L Upright Fire Sprinkler Head
Sprinkler Identification Number (SIN): TY4811
This Upright sprinkler features a Brass finish and a 212°F (100°C) temperature.
This Tyco™ Model TY-L Upright Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 212°F (100°C) with a 8.0 K-Factor, and is rated for light, ordinary hazard occupancies. Each Upright head features a heat-sensitive fusible link assembly, standard 1/2 in. NPT threads, and a Brass frame with Bronze deflector.
This is a standard response, standard coverage, Upright sprinkler with a maximum working water pressure of 175 PSI. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, effectively containing the spread of fire.
The TY4811 is installed in the Upright position.
Tyco™ Upright Fire Sprinkler (TY4811) Sprinkler Head Listings and Approvals
Each sprinkler head is made by Tyco™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this TY4811 maintains the following listings and approvals: UL, C-UL, FM
Refer to the datasheet for listings and approvals in specific temperatures and/or applications.
The Tyco™ Upright Sprinkler TY4811 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet pipe fire protection systems.
Tyco™ TY4811 Automatic Fire Sprinkler Installation and Accessories
During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional installation and storage information.
Listed TY4811 Accessories include:
Sprinkler Wrenches:
- W-Type 9 Standard Sprinkler Wrench
Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.
Available Sprinklers:
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 165F | 53-106-1-165
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 212F | 53-106-1-212
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Brass | 280F | 53-106-1-280
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Chrome | 165F | 53-106-7-165
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Chrome | 212F | 53-106-7-212
Tyco™® TY4811 Model TY-L Upright Sprinkler | SR | 8.0K | Chrome | 280F | 53-106-7-280