Victaulic V27 Horizontal Sidewall Fire Sprinkler | V2738 | Residential | 4.2K | Chrome | 175F

SKU:
V2738CH175

No reviews yet Write a Review
$13.99
Victaulic Fire Sprinkler 4.2K Chrome Residential Horizontal Sidewall 1/2" Quick Response 175F | V2738
Victaulic Fire Sprinkler 4.2K Chrome Residential Horizontal Sidewall 1/2" Quick Response 175F | V2738
Deflector of Victaulic Fire Sprinkler 4.2K Chrome Residential Horizontal Sidewall 1/2" Quick Response 175F | V2738
Side of Victaulic Fire Sprinkler 4.2K Chrome Residential Horizontal Sidewall 1/2" Quick Response 175F | V2738
Side 2 of Victaulic Fire Sprinkler 4.2K Chrome Residential Horizontal Sidewall 1/2" Quick Response 175F | V2738
Threads of Victaulic Fire Sprinkler 4.2K Chrome Residential Horizontal Sidewall 1/2" Quick Response 175F | V2738

  • Buy 100 - 399 and get 5% off
  • Buy 400 or above and get 8% off

Frequently Bought Together:

Victaulic Fire Sprinkler 4.2K Chrome Residential Horizontal Sidewall 1/2" Quick Response 175F | V2738
Inc. Tax
Ex. Tax

Overview

Victaulic V2738 Residential Quick Response Chrome Horizontal Sidewall Fire Sprinkler delivers dependable, competitively priced protection against fire in residential occupancies such as homes and apartments. Using a heat-activated 3mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), lowering ambient temperatures to reduce flashover and facilitating safe escape or rescue.

The Victaulic Model V2738 has a 4.2 K-Factor and installs with 1/2 in. (15 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Quick Response Fire Sprinkler features a chrome finish, die-cast brass frame, bronze deflector, and a beryllium nickel spring with PTFE-taped seal.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13, NFPA 13R, NFPA 13D and local fire code. Each Model V2738 sprinkler is made by Victaulic, a piping-industry manufacturer and trusted producer of fire protection products since 1919.

This product is UL listed & FM approved for use in fire protection systems when accepted by the authority having jurisdiction.

Specifications

Response Type:
Quick Response
Temperature:
175F
Corrosion Resistance:
No
May Contain Lead:
No
Nominal K-Factor:
4.2K
Fire Sprinkler Heat Element:
Glass Bulb
Fire Sprinkler Use Type:
Residential
Fire Sprinkler Head Type:
Horizontal Sidewall
SIN Number:
V2738
Thread Type:
NPT
Model:
V27
UL Listed/FM Approved:
No

Data & Resources

Reviews

No reviews yet

Customers Also Viewed