Victaulic® V3409 Sidewall Sprinkler | SR | 8.0K | Black | 175F | S342CES5B0

SKU:
V3409BL175
Manufacturer Part Number:
S342CES5B0

No reviews yet Write a Review
MSRP: $149.00
$129.50
You save $19.50

Victaulic V3409 Black Horizontal Sidewall 175F | S342CES5B0 | Hero | QRFS

Victaulic V3409 Black Horizontal Sidewall 175F | S342CES5B0 | Hero | QRFS
Victaulic V3409 Black Horizontal Sidewall 175F | S342CES5B0 | Side | QRFS
Victaulic V3409 Black Horizontal Sidewall 175F | S342CES5B0 | Deflector | QRFS
Victaulic V3409 Black Horizontal Sidewall 175F | S342CES5B0 | Family | QRFS
Play Button

  • Buy 100 - 199 and get 3% off
  • Buy 200 or above and get 7% off

Frequently Bought Together:

Victaulic V3409 Black Horizontal Sidewall 175F | S342CES5B0 | Hero | QRFS
Inc. Tax
Ex. Tax
Overview

Victaulic FireLock FL-SR/SW (V3409) Horizontal Sidewall Fire Sprinkler Head

This Victaulic FL-SR/SW Black Horizontal Sidewall Fire Sprinkler features a glass bulb activating at 175F (79C) with a 8.0 K-Factor, and 3/4 in. NPT threads. Each sidewall head features a brass frame and bronze deflector. The manufacturer part number is S342CES5B0, and the Sprinkler Identification Number (SIN) is V3409. In 2019, Victaulic purchased fire sprinkler company Globe. The Globe Equivalent to this sprinkler is GL8171.

Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), drenching the area surrounding a fire to keep it in its place of origin. For recessed sidewall application, refer to data sheet for installation with the Victaulic V34 Recessed Escutcheon.

Victaulic Sidewall Fire Sprinkler FL-SR/SW (V3409) Sprinkler Head Listings and Approvals

Each FL-SR/SW sprinkler is made by Victaulic, a global leader in fire-suppression products. This horizontal sidewall fire sprinkler head maintains UL Listing.

The V3409 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial occupancies. This sidewall sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet piping systems.

Victaulic FL-SR/SW (V3409) 8.0K Sidewall Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 3/4 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This 8.0K sprinkler features a black finish and a 175F (79C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), 286F (141C), and 360F (182C). Finish and temperature combinations available in the “Options” section at the top of this product page.

V3409 listed accessories include the V34-2 Recessed and V34 Open End sprinkler wrenches and the V34 Recessed Escutcheon. Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Specifications
QRFS SKU:
V3409BL175
Manufacturer Part Number:
S342CES5B0
Replaces Manufacturer Part Numbers:
GL8171
Manufacturer:
Victaulic
SIN:
V3409
Model:
FireLock FL-SR/SW
Head Type:
Sidewall
Finish:
Black
Finish Detail:
Flat Black Polyester Painted
Size:
3/4 in.
Size Detail:
3/4 in. NPT Sprinkler
K Factor:
8.0K
Response Type:
Standard Response (SR)
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Bronze Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Escutcheon Type:
Recessed
Length:
2.94 in. (74.68 mm)
Width:
1.94 in. (49.28 mm)
Height:
1.94 in. (49.28 mm)
Weight:
0.33 lb. (0.15 kg)
Available Box/Pack Quantity:
100
Reviews
No reviews yet