Victaulic V34 Horizontal Sidewall Fire Sprinkler | V3409 | Standard Response | 8.0K | Chrome | 155F

SKU:
V3409CH155

No reviews yet Write a Review
$58.50
Victaulic Fire Sprinkler 8.0K Chrome Horizontal Sidewall SR 155F | V3409
Victaulic Fire Sprinkler 8.0K Chrome Horizontal Sidewall SR 155F | V3409
Victaulic Fire Sprinkler 8.0K Chrome Horizontal Sidewall SR 155F | V3409 - Deflector
Victaulic Fire Sprinkler 8.0K Chrome Horizontal Sidewall SR 155F | V3409 - Bottom
Victaulic Fire Sprinkler 8.0K Chrome Horizontal Sidewall SR 155F | V3409 - Top
Victaulic Fire Sprinkler 8.0K Chrome Horizontal Sidewall SR 155F | V3409 - Threads

  • Buy 100 - 399 and get 5% off
  • Buy 400 or above and get 8% off

Frequently Bought Together:

Victaulic Fire Sprinkler 8.0K Chrome Horizontal Sidewall SR 155F | V3409
Inc. Tax
Ex. Tax

Overview

Victaulic V3409 Standard Response Chrome Horizontal Sidewall Fire Sprinkler delivers dependable, competitively priced protection against fire in ordinary-temperature applications. Using a heat-activated 5mm glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 155F (68C), drenching the area surrounding a fire to keep it in its place of origin.

The Victaulic Model V3409 has an 8.0 K-Factor and installs with 3/4 in. (20 mm) National Pipe Thread (NPT), used in fire sprinkler systems throughout the United States. This Standard Response Fire Sprinkler features a chrome finish, die-cast brass frame, bronze deflector, bronze load screw, and a beryllium nickel spring with PTFE-taped seal.

With a maximum working pressure of 175 PSI (12.1 BAR), this horizontal sidewall sprinkler installs on a wall or the side of a beam where ceiling piping is not desirable and may be installed and used in accordance with NFPA 13 and local fire code. Each Model V3409 sprinkler is made by Victaulic, a piping-industry manufacturer and trusted producer of fire protection products since 1919.

This product is UL listed and approved for use in fire protection systems when accepted by the authority having jurisdiction. In accordance with NFPA 13, a higher temperature rating may be required when installing a standard response fire sprinkler in or near heat sources, unventilated spaces, uncovered steam mains, or uninsulated rooftops.

Specifications

Response Type:
Standard Response
Temperature:
155F
Corrosion Resistance:
No
May Contain Lead:
No
Nominal K-Factor:
8.0K
Fire Sprinkler Heat Element:
Glass Bulb
Fire Sprinkler Use Type:
Commercial
Fire Sprinkler Head Type:
Horizontal Sidewall
SIN Number:
V3409
Thread Type:
NPT
Model:
V34
UL Listed/FM Approved:
No

Data & Resources

Reviews

No reviews yet

Customers Also Viewed