Viking™ Mirage ELO QREC Light Hazard Concealed Pendent (VK636) Fire Sprinkler Head
Sprinkler Identification Number (SIN): VK636
This Concealed Pendent sprinkler features a Brass Finish and 200F (93C) activation temperature.
This Viking™ VK636 Mirage ELO (Extra-Large Orifice) EC/QREC Concealed Pendent Fire Sprinkler is a Quick Response, Extended Coverage Concealed Pendent fire sprinkler head, activating at 200F (93C) with a 11.2 K-Factor, and is rated for Light Hazard occupancies. Each Concealed Pendent head features a heat-sensitive fusible link assembly, standard 3/4 in. NPT threads, and a brass frame with a bronze deflector.
VK636 includes a pre-assembled threaded adapter for easy installation of a low-profile cover plate with up to 1/2” (13 mm) vertical adjustment. The two-piece design allows for sprinkler installation and testing before attaching the cover plate. The "push-on" and "thread-on" cover plate options ensure easy installation after system testing and ceiling finishing. Available VK636 Mirage ELO Cover Plates Listed Below.
The Viking™ Mirage ELO VK636 is a glass-bulb sprinkler designed for concealed pipe systems, ideal for areas where a smooth ceiling appearance is preferred. With a K-factor of 11.2, the sprinkler produces flows required to meet Light Hazard density requirements at lower pressures than 5.6K or 8.0K sprinklers.
The Viking™ Quick Response Extra-Large Orifice Sprinkler delivers higher water flow at lower pressures compared to standard or large orifice sprinklers, making it ideal for areas with limited water pressure. This design may reduce or eliminate the need for a fire pump. In existing systems, upgrading to extra-large orifice sprinklers can provide the increased water density needed to support higher hazard classifications.
This is a Quick Response, Extended Coverage Concealed Pendent sprinkler with a maximum working water pressure of 175 PSI (12 BAR). The VK636 Mirage ELO Sprinkler pairs reliable fire protection with a clean, flush profile. Using a heat-activated fusible link assembly, this automatic fire sprinkler opens when ambient temperatures reach the sprinkler’s listed activation temperature, drenching the area surrounding a fire to keep it in its place of origin.
Viking™ Mirage ELO QREC Light Hazard Fire Sprinkler VK636 Sprinkler Head Listings and Approvals
Each Mirage ELO sprinkler is made by Viking™, a global leader in fire protection manufacturing. When installed properly, this VK636 fire sprinkler head maintains listings and approvals:
cULus
Refer to the datasheet for up-to-date listings and approvals in specific temperatures and/or applications.
When using Viking™ Concealed Pendent Sprinkler VK636 for systems designed to NFPA standards, apply the listed areas of coverage and minimum water supply requirements shown in the manufacturer datasheet. This Concealed Pendent sprinkler head has a maximum working pressure of 175 PSI (12 BAR) and connects to wet piping systems.
Viking™ (VK636) Mirage ELO Concealed Pendent Sprinkler Installation and Other Information
The VK636 Concealed Pendent Sprinkler is recessed in the Concealed Pendent orientation. Refer to the manufacturer data sheet for installation instructions with the approved Viking™ cover plates and accessories. During installation be aware that over tightening will cause permanent damage to the 3/4 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 20 ft-lb (27.1 N-m). Refer to the data sheet for additional installation and storage information.
Temperature options include 165F (74C) and 200F (93C)
The VK636 listed wrenches include the approved Viking™ Mirage ELO Heavy Duty Sprinkler Wrench (15467W/B). Add the correct wrench for your VK636 Concealed Pendent installation! Available VK636 Mirage ELO Cover Plates Listed Below.
Available Viking™ VK636 Concealed Pendent Sprinklers & Listed Accessories:
Viking™® VK636 Mirage ELO Light Hazard Concealed Pendent Sprinkler | EC | QR | 11.2 | Brass | 165F | 3/4 in. NPT | 16102AC
Viking™® VK636 Mirage ELO Light Hazard Concealed Pendent Sprinkler | EC | QR | 11.2 | Brass | 205F | 3/4 in. NPT | 16102AE
Wrenches:
Fire Sprinkler Wrench | Viking™ Mirage QR ELO Heavy Duty | Concealed | 15467W/B
Cover Plates:
Push On:
Viking™ Mirage ELO | Circular | 3-5/16 in. OD | 15765
Thread On:
Viking™ Mirage ELO | Circular | 3-5/16 in. OD | 23495