CPVC QuickTorque™ SR Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Metal Thread | Spears FlameGuard™ | 4235-130GMR

SKU:
51-SP-FSA-QT-160800
Manufacturer Part Number:
4235-130GMR
$9.06
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-FSA-QT-160800
Manufacturer Part Number:
4235-130GMR
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Adapter
Size:
1 in. x 1/2 in.
Size Detail:
1 in. x 1/2 in. Head Adapter
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC QuickTorque™ SR Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Metal Thread | Spears FlameGuard™ | 4235-130GMR

CPVC QuickTorque™ SR Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Metal Thread | Spears FlameGuard™ | 4235-130GMR
CPVC QuickTorque™ SR Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Metal Thread | Spears FlameGuard™ | 4235-130GMR
CPVC QuickTorque™ SR Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Metal Thread | Spears FlameGuard™ | 4235-130GMR
CPVC QuickTorque™ SR Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Metal Thread | Spears FlameGuard™ | 4235-130GMR
Play Button
Overview

CPVC QuickTorque™ SR Female Sprinkler Head Adapter — 1 in. x 1/2 in. Gasket Sealed Metal Thread — Spears FlameGuard™ — 4235-130GMR

The Spears FlameGuard™ QuickTorque™ SR 1 in. x 1/2 in. female sprinkler head adapter connects CPVC pipe to metal sprinkler heads in wet fire sprinkler systems. It features a gasket-sealed metal thread for fast installation and a reliable, watertight connection. The QuickTorque™ SR design provides torque control to prevent over-tightening and reduce stress on the CPVC body. Manufactured from fire-protection-grade CPVC, it offers excellent corrosion resistance and high strength. The socket end connects to CPVC pipe using ASTM F493-compliant solvent cement to form a permanent, leak-free seal. UL Listed and FM Approved, this fitting complies with NFPA 13, NFPA 13R, and NFPA 13D standards. Rated for 175 psi and up to 150°F, it’s suitable for residential and light-hazard applications.

Install per Spears FlameGuard™ instructions for cleaning, cementing, and sprinkler head assembly. Use approved CPVC sealant and adhere to torque specifications. The gasket-sealed design ensures consistent sealing performance and long service life. This adapter provides a corrosion-resistant, UL/FM-approved connection between CPVC pipe and sprinkler heads, ensuring safe and efficient performance in wet fire sprinkler systems.