CPVC TorqueSafe™ Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-130GS

SKU:
51-SP-FSA-TS-BR-160800
Manufacturer Part Number:
4235-130GS
$7.76
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-FSA-TS-BR-160800
Manufacturer Part Number:
4235-130GS
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Adapter
Size:
1 in. x 1/2 in.
Size Detail:
1 in. x 1/2 in. Head Adapter
Thread Size:
1/2 in.
Thread Material:
Brass
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC TorqueSafe™ Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-130GS | Hero

CPVC TorqueSafe™ Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-130GS | Hero
CPVC TorqueSafe™ Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-130GS | Side
CPVC TorqueSafe™ Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-130GS | Installed
CPVC TorqueSafe™ Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-130GS | Outlet
CPVC TorqueSafe™ Female Sprinkler Head Adapter | 1 in. x 1/2 in. Gasket Sealed Brass Thread | Spears FlameGuard™ | 4235-130GS | Inlet
Play Button
Overview

CPVC TorqueSafe™ Female Sprinkler Head Adapter — 1 in. x 1/2 in. Gasket Sealed Brass Thread — Spears FlameGuard™ — 4235-130GS

The Spears FlameGuard™ TorqueSafe™ 1 in. x 1/2 in. female sprinkler head adapter connects CPVC piping to brass sprinkler heads in wet fire sprinkler systems. Constructed from fire-protection-grade CPVC, it includes a brass insert with a gasket-sealed female thread that ensures a watertight, reusable connection. The TorqueSafe™ design features a built-in stop that prevents overtightening and minimizes stress on the CPVC body. The socket end bonds to CPVC pipe using ASTM F493-approved solvent cement to create a secure, permanent seal. UL Listed and FM Approved, this fitting meets NFPA 13, NFPA 13R, and NFPA 13D standards. Rated for 175 psi and 150°F maximum service temperature, it’s ideal for residential and light-hazard fire sprinkler systems.

Follow Spears FlameGuard™ installation instructions for pipe preparation, solvent cementing, and sprinkler head assembly. Use CPVC-approved thread sealant and adhere to recommended torque settings. The gasket seal ensures consistent, leak-free performance and extends service life by reducing thread wear. This adapter offers a durable, corrosion-resistant, and code-compliant connection that meets UL and FM listing requirements for CPVC wet fire sprinkler systems.

Reviews
No reviews yet
Product Alternatives