Victaulic Series 751 Alarm Check Valve | 2 in. Grooved x Grooved | Ductile Iron | 300 PSI
2-inch UL Listed and FM Approved alarm check valve for NFPA-compliant wet pipe fire sprinkler systems
The Victaulic Series 751 Alarm Check Valve is a high-performance fire protection valve designed for wet pipe fire sprinkler systems. This 2-inch grooved alarm check valve combines compact design, durable ductile iron construction, and dependable alarm functionality to meet the rigorous demands of commercial, industrial, and institutional fire protection applications. With grooved end connections for fast installation and a 300 PSI pressure rating, it is an ideal solution for projects requiring reliable, code-compliant NFPA 13 fire sprinkler system valves.
How the Victaulic Alarm Check Valve Works
In normal operation, the internal clapper remains closed to stop water from flowing backward into the supply line. When a sprinkler activates and water flows forward, the clapper opens to allow system operation. At the same time, the valve’s trim directs a portion of water to the alarm line, which can be connected to a hydraulic water motor gong or an electrical pressure switch (sold separately). This feature provides immediate waterflow notification, a critical requirement for UL Listed and FM Approved fire sprinkler systems.
Installation and Maintenance
The Series 751 is engineered for vertical installations with upward flow through the valve. Its grooved end connections make it quick to install using standard couplings, reducing labor compared to flanged or threaded options. All trim ports are threaded for compatibility with standard fire protection fittings, and internal components can be accessed without removing the valve from the system. This design simplifies inspection and maintenance, helping to keep fire sprinkler systems in compliance with NFPA requirements.
Key Features of the Victaulic 2-Inch Alarm Check Valve
- 2 in. grooved inlet × 2 in. grooved outlet (2.375 in. OD)
- Maximum working pressure: 300 PSI
- Dual function: check valve performance and waterflow alarm initiation
- Compatible with hydraulic alarms or electric pressure switches (sold separately)
- Designed for vertical, upward flow installations
- Compact, lightweight design with ductile iron body
- NPT threaded auxiliary connections for alarm, drain, and test lines
- Serviceable in place for easier inspections and maintenance
- UL Listed and FM Approved for fire protection use
Applications
The Victaulic Series 751 Alarm Check Valve is commonly used in:
- Wet pipe sprinkler systems in small to mid-sized commercial and industrial buildings
- Fire protection risers where grooved connections speed up installation
- Projects requiring compact, lightweight valves with full NFPA 13 compliance
- Systems paired with water motor gongs or pressure switches for reliable alarm signaling
Certifications and Approvals
- UL Listed
- FM Approved
- NFPA 13 Compliant