Victaulic Series 751 Alarm Check Valve | 4 in. Grooved x Grooved | Ductile Iron | 300 PSI
4-inch UL Listed and FM Approved alarm check valve for NFPA-compliant wet pipe fire sprinkler systems
The Victaulic Series 751 Alarm Check Valve is a reliable fire protection valve designed for wet pipe fire sprinkler systems. This 4-inch grooved alarm check valve provides durable construction, dependable alarm functionality, and easy installation. With grooved end connections for faster assembly and a 300 PSI pressure rating, it is ideal for commercial, industrial, and institutional fire protection systems where code compliance and long-term performance are essential.
How the Victaulic Alarm Check Valve Works
Under normal operating conditions, the clapper remains closed to prevent reverse flow into the supply piping. When a sprinkler activates and water begins flowing forward, the clapper opens. At the same time, the valve’s internal trim diverts water to the alarm line, which may be connected to a water motor alarm gong or an electric pressure switch (sold separately). This provides immediate notification of waterflow, meeting NFPA 13 requirements for fire protection systems.
Installation and Maintenance
The Series 751 is designed for vertical installations with upward flow through the valve. Grooved end connections allow quick installation with standard couplings, reducing labor and material costs compared to flanged systems. All auxiliary ports are threaded for compatibility with standard fire protection trim and fittings. Internal components are accessible in place, making inspection and maintenance faster and more efficient for building owners and contractors.
Key Features of the Victaulic 4-Inch Alarm Check Valve
- 4 in. grooved inlet × 4 in. grooved outlet
- Maximum working pressure: 300 PSI
- Dual function: check valve performance and alarm initiation
- Compatible with hydraulic alarms or electric pressure switches (sold separately)
- Designed for vertical, upward flow installations
- Ductile iron body with compact, service-friendly design
- NPT threaded auxiliary connections for alarm, drain, and test lines
- Internal parts accessible without removing the valve from the system
- UL Listed and FM Approved for fire protection use
Applications
The Victaulic Series 751 Alarm Check Valve is widely used in:
- Wet pipe sprinkler systems in mid-sized to large commercial and industrial facilities
- Riser assemblies where grooved connections provide faster installation
- Projects requiring NFPA 13 compliance with UL/FM certified components
- Systems paired with pressure switches or water motor gongs for waterflow notification
Certifications and Approvals
- UL Listed
- FM Approved
- NFPA 13 Compliant