Viking™ Escutcheon Installation Tool for Institutional Fire Sprinklers | 10551W/B

SKU:
16-VK-10551
Manufacturer Part Number:
10551W/B
$68.94
Data Sheet Product Data Sheet

Select Variation

  • Buy 10 - 99 and get 5% off
  • Buy 100 or above and get 10% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
Material:
Steel
SIN:
Escutcheons for VK426, VK427, VK650, VK651
Model:
Viking™ Institutional
Manufacturer:
Viking™
FM Approved:
Not Required
UL Listed:
Not Required

Viking™ Escutcheon Installation Tool for Institutional Fire Sprinklers | 10551W/B | Hero

Viking™ Escutcheon Installation Tool for Institutional Fire Sprinklers | 10551W/B | Hero
Viking™ Escutcheon Installation Tool for Institutional Fire Sprinklers | 10551W/B | Top
Viking™ Escutcheon Installation Tool for Institutional Fire Sprinklers | 10551W/B | Side
Viking™ Escutcheon Installation Tool for Institutional Fire Sprinklers | 10551W/B | Alt Side
Data & Resources
Overview

The Viking™ Institutional Escutcheon Installation Tool is designed to quickly secure Viking™'s 19650 and 19651 escutcheon plates. Institutional fire sprinklers work to reduce water damage and costly fire sprinkler replacement with a flush, tamper-resistant design. These institutional escutcheons and sprinklers are used in prisons, jails, secure mental health facilities, and other environments where vandalism or self-harm are a concern.

The Viking™ 10551W/B escutcheon installation tool is compatible with Viking™'s 3 in. and 4 in. institutional escutcheons, including those with the following part numbers:

  • 19650F
  • 19650M/W
  • 19650M (RAL9006)
  • 19651F
  • 19651M/W
  • 19651M (RAL9006)

Viking™'s institutional escutcheons are found on a variety of pendent and horizontal sidewall fire sprinklers, including those with the following sprinkler identification numbers (SINs):

  • VK426
  • VK427
  • VK650
  • VK651

How do I install Viking™'s institutional escutcheons with the 10551W/B?

Use this tool only in accordance with Viking™'s official installation guides for each sprinkler. Installation typically follows these steps:

  • Before securing the escutcheon, place it on the sprinkler (without the locking ring) to confirm that the water supply pipe is of the correct length. Then, install the locking ring.
  • Secure Viking™'s 10551W/B escutcheon tool to the escutcheon by connecting the four indentations on the escutcheon ring to the tabs on the tool.
  • Rotate the institutional escutcheon clockwise until the four arms of the locking ring engage and the plate fits tightly against the wall or ceiling.
  • Rotate the plate an additional half-turn clockwise.