Viking™ VK467 Upright Sprinkler | Residential | 4.9K | Chrome | 175F | 19154FD

SKU:
VK467CH175
Manufacturer Part Number:
19154FD
$40.99
  • Buy 50 - 99 and get 3% off
  • Buy 100 or above and get 7% off

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
VK467CH175
Manufacturer Part Number:
19154FD
Manufacturer:
Viking™
SIN:
VK467
Model:
Freedom
Head Type:
Upright
Finish:
Chrome
Finish Detail:
Chrome
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
4.9K
Response Type:
Residential
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Brass Frame, Brass Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
No
Maximum Working Water Pressure:
175 PSI
Length:
1.71 in. (43.43 mm)
Width:
1.71 in. (43.43 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.15 lb. (0.07 kg)

Viking™ VK467 Upright Sprinkler | Residential | 4.9K | Chrome | 175F | 19154FD | QRFS™ | Hero

Viking™ VK467 Upright Sprinkler | Residential | 4.9K | Chrome | 175F | 19154FD | QRFS™ | Hero
Viking™ VK467 Upright Sprinkler | Residential | 4.9K | Chrome | 175F | 19154FD | QRFS™ | Side
Viking™ VK467 Upright Sprinkler | Residential | 4.9K | Chrome | 175F | 19154FD | QRFS™ | Deflector
Viking™ VK467 Upright Sprinkler | Residential | 4.9K | Chrome | 175F | 19154FD | QRFS™ | Family
Play Button
Overview

Viking™ Freedom Residential Upright (VK467) Fire Sprinkler Head

This Viking™ Freedom Residential Upright Fire Sprinkler features a glass bulb activating at 175F (79C) with a 4.9 K-Factor, and 1/2 in. NPT threads. Each upright head features a brass frame and bronze deflector. The Sprinkler Identification Number (SIN) is VK467. This is a residential response, standard coverage sprinkler with a maximum working water pressure of 175 PSI.

The VK467 residential upright sprinkler delivers effective, affordable defense against fire in residential occupancies. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), drenching the area surrounding a fire to keep it in its place of origin.

Viking™ Residential Upright Fire Sprinkler Freedom (VK467) Sprinkler Head Listings and Approvals

Each VK467 sprinkler head is made by Viking™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this fire sprinkler head maintains listings and approvals from cULus (Category VKKW) and is NYC Approved (MEA 89-92-E, Volume 35). Refer to the datasheet for listings and approvals in specific temperatures and/or applications.

When using Viking™ Residential Upright Sprinkler VK467 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on the datasheet. This upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) UL and connects to wet piping systems.

Viking™ Freedom (VK467) Upright Sprinkler Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the residential sprinkler head (upright type). Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This upright sprinkler head features a chrome finish and a 175F (79C) temperature. Available finish options include Brass, Chrome, White, and Black. White Polyester Painted (White), and Flat Black Polyester Painted (Black) are UL Listed as corrosion resistant. Temperature options include 155F (68C) and 175F (79C). Finish and temperature combinations available in the “Options” section at the top of this product page.

The VK467 listed accessories include the approved Viking™ Wrench (part no. 21475M/B). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page.

Reviews
No reviews yet
Product Alternatives