Tyco AV-1-300 Alarm Check Valve | 2-1/2 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-110

SKU:
70-TY-ACHKGG-21
Manufacturer Part Number:
52-203-1-110
$1,867.27

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Due to custom manufacturing, this item cannot be returned. Learn more

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
70-TY-ACHKGG-21
Manufacturer Part Number:
52-203-1-110
Manufacturer:
Tyco™
Valve Type:
Alarm Check Valve
Number Of Connections:
2
Connection Type:
Groove x Groove
Body Material:
Ductile Iron
Clapper:
Single
Size:
2-1/2 in.
Size Detail:
2-1/2 in. Groove x 2-1/2 in. Groove
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
300 PSI
Auxillary Connection Type:
NPT
Finish:
Red
Installation:
Vertical or Horizontal
Weight:
22 lbs. (9.98 kg.)

Tyco AV-1-300 Alarm Check Valve | 2-1/2 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-110

Tyco AV-1-300 Alarm Check Valve | 2-1/2 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-110
Tyco AV-1-300 Alarm Check Valve | 2-1/2 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-110
Tyco AV-1-300 Alarm Check Valve | 2-1/2 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-110
Overview

Tyco AV-1-300 Alarm Check Valve | 2½ in. Groove x Groove | Ductile Iron | 300 PSI

The Tyco AV-1-300 Alarm Check Valve is designed for use in wet fire sprinkler systems and provides dependable, automatic operation. This 2½ inch model features grooved connections on both the inlet and outlet, making it ideal for systems using flexible or rigid grooved couplings. With a ductile iron body and a rated working pressure of 300 PSI, it provides reliable protection in a wide range of commercial and industrial fire protection applications.

This valve serves two critical functions: it prevents backflow into the water supply and signals alarm conditions when water begins to move through the system. When pressure increases during a sprinkler activation, the internal clapper opens to allow forward flow. A portion of this water is diverted through a built-in bypass trim, which can be connected to a hydraulic alarm bell or pressure switch (not included) to notify building occupants or monitoring systems of system activation.

The AV-1-300 supports both horizontal and vertical installation. For horizontal use, the drain outlet must face downward. For vertical configurations, the flow direction must be upward through the valve. This flexibility makes it easier to integrate into a variety of wet system riser layouts while maintaining compliance with NFPA 13 installation requirements.

All auxiliary ports in the trim assembly—such as those for alarm lines, test valves, and drains—are NPT threaded to ensure compatibility with standard fittings. The valve’s internal components can be accessed for inspection or maintenance without removing it from the piping system, helping reduce service time during routine checks.

Key Features

  • For use in wet fire sprinkler systems only
  • 2½ inch Groove x Groove connections for flexible installation
  • 300 PSI maximum working pressure
  • Prevents reverse flow and initiates alarm during system activation
  • Supports horizontal (drain down) and vertical (flow up) installation
  • Trim assembly includes NPT threaded connections for alarm, test, and drain lines
  • Clapper design allows forward flow and seals against backflow
  • Serviceable without removing valve from installed piping

Common Applications

  • Commercial, industrial, and institutional wet sprinkler systems
  • System risers or other areas needing backflow prevention and alarm signaling
  • Compatible with water motor gongs and pressure switches (sold separately)

Listings and Approvals

  • UL Listed
  • C-UL Listed
  • FM Approved

The Tyco AV-1-300 Alarm Check Valve (2½ in. Groove x Groove) provides strong, field-tested performance in wet sprinkler systems. Its all-grooved connections, durable construction, and alarm-ready design make it a smart and compliant choice for contractors and engineers alike.