Tyco AV-1-300 Alarm Check Valve | 6 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-115

SKU:
70-TY-ACHKGG-26
Manufacturer Part Number:
52-203-1-115
$2,227.10

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Due to custom manufacturing, this item cannot be returned. Learn more

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
70-TY-ACHKGG-26
Manufacturer Part Number:
52-203-1-115
Manufacturer:
Tyco™
Valve Type:
Alarm Check Valve
Number Of Connections:
2
Connection Type:
Groove x Groove
Body Material:
Ductile Iron
Clapper:
Single
Size:
6 in.
Size Detail:
6 in. Groove x 6 in. Groove
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
300 PSI
Auxillary Connection Type:
NPT
Finish:
Red
Installation:
Vertical or Horizontal
Weight:
58 lbs. (26.31 kg.)

Tyco AV-1-300 Alarm Check Valve | 6 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-115

Tyco AV-1-300 Alarm Check Valve | 6 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-115
Tyco AV-1-300 Alarm Check Valve | 6 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-115
Tyco AV-1-300 Alarm Check Valve | 6 in. Groove x Groove | Ductile Iron | 300 PSI | 52-203-1-115
Overview

Tyco AV-1-300 Alarm Check Valve | 6 in. Groove x Groove | Ductile Iron | 300 PSI

The Tyco AV-1-300 Alarm Check Valve is a dependable solution for wet fire sprinkler systems, combining one-way flow control with alarm signaling capability. This 6-inch model features grooved connections on both the inlet and outlet, making it compatible with a wide range of grooved coupling systems for fast, flexible installation. Its ductile iron body is rated for 300 PSI maximum working pressure, providing strength and durability in demanding fire protection environments.

Designed for use in NFPA 13-compliant wet pipe systems, the AV-1-300 prevents backflow while enabling alarm activation when water begins to move through the system. When forward flow occurs—typically due to sprinkler activation—the valve’s clapper opens. At the same time, water is diverted through an internal bypass trim, which can be connected to a water motor gong or pressure switch (not included) for local or remote alarm signaling.

This model supports both horizontal and vertical installation, offering flexibility for system layout. When installed horizontally, the drain port must face downward. For vertical configurations, water must flow upward through the valve. These orientation options make it easier to integrate the valve into new or existing risers or system branches.

The included trim features NPT threaded ports for alarm, test, and drain connections. Internal components are accessible for inspection and maintenance without removing the valve from the pipe, minimizing downtime during routine service.

Key Features

  • For use in wet fire sprinkler systems only
  • 6 inch Groove x Groove connections for flexible pipe compatibility
  • Rated for 300 PSI maximum working pressure
  • Acts as both a check valve and alarm initiator
  • Supports horizontal (drain down) and vertical (flow up) installation
  • NPT threaded trim ports for alarm, drain, and test valves
  • Clapper opens with forward flow and seals tightly against backflow
  • Internal parts serviceable without removing the valve from piping

Common Applications

  • Wet sprinkler systems in commercial, industrial, or institutional buildings
  • System risers or branches using grooved piping and couplings
  • Used with water motor gongs or pressure switches (sold separately)

Listings and Approvals

  • UL Listed
  • C-UL Listed
  • FM Approved

The Tyco AV-1-300 Alarm Check Valve (6 in. Groove x Groove) offers strong performance, easy installation, and reliable operation. It’s a trusted choice for contractors and engineers seeking a grooved-end alarm valve solution for NFPA-compliant wet fire protection systems.