Tyco AV-1-300 Alarm Check Valve | 2½ in. Flange x Groove | Ductile Iron | 300 PSI
The Tyco AV-1-300 Alarm Check Valve is engineered for use in wet fire sprinkler systems, combining dependable one-way flow control with alarm signaling capability. This model features a 2½ inch flanged inlet and a grooved outlet, along with a ductile iron body rated for a maximum working pressure of 300 PSI. It helps ensure reliable fire protection by preventing reverse water flow and activating an alarm when system water begins to move.
Designed for versatility, this valve supports both horizontal and vertical installation, provided proper orientation is followed. For horizontal installations, the drain connection must face downward. For vertical installations, water must flow upward through the valve. This flexibility allows the AV-1-300 to accommodate a variety of system layouts without compromising performance or compliance.
When water flows forward with sufficient force, the internal clapper opens and allows water to pass into the sprinkler system. At the same time, a portion of this water is diverted through an internal bypass trim to a hydraulic alarm bell or pressure switch (not included). All auxiliary connections on the valve, including the alarm line, drain, and gauge ports, are NPT threaded for compatibility with standard fittings and accessories.
The ductile iron body offers superior strength and long-term durability, while internal corrosion-resistant components help reduce wear and extend service life. All internal parts can be accessed for maintenance without removing the valve from the piping system, which simplifies inspections and routine servicing.
Key Features
- For use in wet pipe fire sprinkler systems only
- 2½ inch Flanged inlet x 2½ inch Grooved outlet
- Rated for 300 PSI maximum working pressure
- Prevents backflow and activates alarm during waterflow events
- Can be installed horizontally (drain facing down) or vertically (flow upward)
- Internal trim routes water to hydraulic bell or pressure switch
- All auxiliary connections (drain, gauge, alarm line) are NPT threaded
- Hinged clapper design allows forward flow, seals against reverse flow
- Access to internal components without removing valve from piping
Common Applications
- Commercial, industrial, and institutional wet sprinkler systems
- Use in system risers or other areas requiring both backflow prevention and alarm functionality
- Compatible with water motor gongs and pressure switches (sold separately)
Listings and Approvals
- UL Listed
- C-UL Listed
- FM Approved
The Tyco AV-1-300 Alarm Check Valve offers a durable, field-proven solution for contractors and engineers installing or maintaining NFPA 13-compliant wet fire protection systems. Its compact footprint, flexible orientation, and reliable operation make it a go-to choice for dependable alarm valve performance.