Tyco AV-1-300 Alarm Check Valve | 6 in. Flange x Flange | Ductile Iron | 300 PSI
The Tyco AV-1-300 Alarm Check Valve is a reliable, dual-purpose component used in wet fire sprinkler systems to prevent backflow and trigger alarms when water begins to move. This 6-inch model features flanged connections on both the inlet and outlet, making it ideal for rigid systems that require bolted flanged joints. Built with a ductile iron body and rated for up to 300 PSI, it offers high strength and long-lasting performance in a wide range of fire protection applications.
Under normal conditions, the valve’s internal clapper remains closed, preventing reverse flow from the system side back into the water supply. When system pressure increases during sprinkler activation, the clapper opens to allow forward flow. Simultaneously, water is diverted through an internal bypass trim, which can be piped to a hydraulic alarm bell or pressure switch (not included) to provide an alert of system activation.
This valve can be installed in either a horizontal or vertical orientation, provided the flow direction and drain positioning are correct. For horizontal installations, the drain port must point downward. For vertical setups, water must flow upward through the valve. This flexibility simplifies integration into riser assemblies and other system layouts.
The trim assembly includes ports for alarm, test, and drain lines, all of which are NPT threaded for compatibility with standard fittings. The internal components are accessible without removing the valve from the piping, which helps streamline routine maintenance and inspections.
Key Features
- For use in wet fire sprinkler systems only
- 6 inch Flanged inlet and 6 inch Flanged outlet
- Rated for 300 PSI maximum working pressure
- Dual function: check valve and alarm signal activation
- Horizontal and vertical installation options
- NPT threaded trim connections for drain, test, and alarm lines
- Clapper design ensures one-way flow and backflow prevention
- Serviceable in-place without disconnecting from piping
Common Applications
- Wet pipe sprinkler systems in commercial, industrial, and institutional settings
- System risers or valve stations requiring flanged pipe connections
- Used with water motor alarms or pressure switches for flow notification (sold separately)
Listings and Approvals
- UL Listed
- C-UL Listed
- FM Approved
The Tyco AV-1-300 Alarm Check Valve (6 in. Flange x Flange) offers strong mechanical performance, alarm capability, and installation flexibility. It's a trusted choice for contractors and system designers looking for flanged connectivity and long-term reliability in wet fire protection systems.