Tyco AV-1-300 Alarm Check Valve | 6 in. Flange x Groove | Ductile Iron | 300 PSI | 52-203-1-615

SKU:
70-TY-ACHKFG-26
Manufacturer Part Number:
52-203-1-615
$2,226.75

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Due to custom manufacturing, this item cannot be returned. Learn more

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
70-TY-ACHKFG-26
Manufacturer Part Number:
52-203-1-615
Manufacturer:
Tyco™
Valve Type:
Alarm Check Valve
Number Of Connections:
2
Connection Type:
Flange x Groove
Body Material:
Ductile Iron
Clapper:
Single
Size:
6 in.
Size Detail:
6 in. Flange x 6 in. Groove
UL Listed:
Yes
FM Approved:
Yes
Rated Working Water Pressure:
300 PSI
Auxillary Connection Type:
NPT
Finish:
Red
Installation:
Vertical or Horizontal
Weight:
70 lbs. (31.75 kg.)

Tyco AV-1-300 Alarm Check Valve | 6 in. Flange x Groove | Ductile Iron | 300 PSI | 52-203-1-615

Tyco AV-1-300 Alarm Check Valve | 6 in. Flange x Groove | Ductile Iron | 300 PSI | 52-203-1-615
Tyco AV-1-300 Alarm Check Valve | 6 in. Flange x Groove | Ductile Iron | 300 PSI | 52-203-1-615
Tyco AV-1-300 Alarm Check Valve | 6 in. Flange x Groove | Ductile Iron | 300 PSI | 52-203-1-615
Tyco AV-1-300 Alarm Check Valve | 6 in. Flange x Groove | Ductile Iron | 300 PSI | 52-203-1-615
Overview

Tyco AV-1-300 Alarm Check Valve | 6 in. Flange x Groove | Ductile Iron | 300 PSI

The Tyco AV-1-300 Alarm Check Valve is a key component in wet fire sprinkler systems, designed to prevent reverse water flow and provide reliable alarm signaling during system activation. This 6-inch model features a flanged inlet and a grooved outlet, offering versatility for systems that transition from rigid flanged pipe to grooved couplings. Its ductile iron body is rated for a maximum working pressure of 300 PSI, providing durability and performance in demanding fire protection applications.

During normal conditions, the valve's clapper remains closed to block backflow from the system side. When a sprinkler activates and water flows forward, the clapper opens. Some of this water is routed through the valve’s built-in bypass trim, which can be connected to a hydraulic alarm bell or pressure switch (not included) to signal an alarm condition.

This valve supports both horizontal and vertical installation. When installed horizontally, the drain must face downward. In vertical configurations, water must flow upward. This flexible installation orientation allows it to fit a wide range of system layouts while remaining compliant with NFPA 13 standards.

The trim assembly includes connections for an alarm line, test valve, and drain—all of which are NPT threaded for compatibility with standard fire protection fittings. Maintenance is simplified, as the valve’s internal components can be accessed without removing the valve body from the piping system.

Key Features

  • For use in wet fire sprinkler systems only
  • 6 inch Flanged inlet x 6 inch Grooved outlet
  • Rated for 300 PSI maximum working pressure
  • Prevents backflow and initiates system alarms during activation
  • Supports horizontal (drain facing down) and vertical (flow up) installation
  • NPT threaded trim ports for alarm, test, and drain connections
  • Clapper opens under forward flow and seals against reverse flow
  • Internal components accessible for service without pipe removal

Common Applications

  • Wet sprinkler systems in commercial, industrial, and institutional buildings
  • Used in risers where flanged inlets meet grooved downstream piping
  • Compatible with pressure switches and water motor alarms (sold separately)

Listings and Approvals

  • UL Listed
  • C-UL Listed
  • FM Approved

The Tyco AV-1-300 Alarm Check Valve (6 in. Flange x Groove) offers rugged construction, alarm-ready functionality, and flexible connection options. It’s a reliable solution for contractors and system designers building NFPA-compliant wet fire protection systems.