Tyco AV-1-300 Alarm Check Valve | 8 in. Flange x Flange | Ductile Iron | 300 PSI
The Tyco AV-1-300 Alarm Check Valve is a robust and reliable component for wet pipe fire sprinkler systems. This 8-inch model features flanged connections on both the inlet and outlet, making it ideal for systems that require fully flanged, rigid piping. Constructed with a ductile iron body and rated for a maximum working pressure of 300 PSI, this valve is built to perform in large-scale commercial, industrial, and institutional fire protection applications.
In standard operation, the internal clapper remains closed to prevent water from flowing backward into the supply. When a sprinkler activates and water begins to flow forward, the clapper opens. Simultaneously, the valve’s internal bypass trim diverts a portion of the flow to an alarm line, which can be connected to a hydraulic alarm bell or pressure switch (not included). This provides essential notification of waterflow in the system.
The AV-1-300 is approved for both horizontal and vertical installations. In horizontal applications, the drain connection must face downward. For vertical use, water must flow upward through the valve. This installation flexibility makes it easy to incorporate into a wide range of system designs, while supporting full compliance with NFPA 13 requirements.
All trim connections, including those for the alarm, test valve, and main drain, are NPT threaded for compatibility with standard fire protection fittings. Internal components can be accessed without removing the valve from the piping system, streamlining inspection and maintenance.
Key Features
- Designed for wet pipe fire sprinkler systems
- 8 inch Flanged inlet x 8 inch Flanged outlet
- 300 PSI maximum working pressure
- Provides both check valve function and alarm initiation
- Horizontal or vertical installation (with proper flow orientation)
- NPT threaded auxiliary ports for alarm, drain, and test lines
- Clapper opens with forward flow and seals tightly against backflow
- Accessible internal components for in-place servicing
Common Applications
- Wet sprinkler systems in large commercial and industrial buildings
- Riser assemblies requiring full flange-to-flange pipe connections
- Used with pressure switches or water motor alarms (sold separately)
Listings and Approvals
- UL Listed
- C-UL Listed
- FM Approved
The Tyco AV-1-300 Alarm Check Valve (8 in. Flange x Flange) is a high-performance solution for fully flanged fire sprinkler system installations. With its durable construction, dual-function design, and serviceable layout, it provides long-term reliability and NFPA-compliant performance for large-scale fire protection systems.