1 1/2" x 1 1/2" x 1" CPVC Slip Outlet-Reducing Tee

SKU
TCPVCRT553
1 1/2" x 1 1/2" x 1" CPVC Slip Outlet-Reducing Tee has a 1 1/2" run, another 1 1/2" run, and a 1" outlet. Ideal for NFPA 13, NFPA 13D, and NFPA 13R fire sprinkler systems, this UL & FM approved CPVC fitting is heat-resistant and made in the USA!
$4.88
SKUNominal DiameterRun 1 Diameter (Inside)Run 2 Diameter (Inside)
TCPVCRT553 1 1/2" x 1 1/2" x 1" 1 1/2" 1 1/2"
Outlet Diameter (Inside)DesignMaterialWorking Pressure
1" Slip Outlet-Reducing Tee Chlorinated Polyvinyl Chloride (CPVC) to Cell Class 2344-7B (ASTM D1784) 175 PSI at 150F (65C)
Temperature RangeListingsThermafit Industries Part NumberAvailability
35F to 150F (2C to 65C) UL-Listed and FM-Approved. UL listed for Light Hazard Occupancies (NFPA 13) and Residential & Home Fire Sprinkler Systems (NFPA 13D, NFPA 13R) CPRT-1121121 Usually Ships Within 48 Hours

Product Description

1 1/2" x 1 1/2" x 1" CPVC Slip Outlet-Reducing Tee is a corrosion-resistant CPVC thermoplastic fitting for use with fire sprinkler pipe. This CPVC outlet-reducing tee features three female socket connections used to split the flow of water into two directions. This tee has a 1 1/2" run, another 1 1/2" run, and a 1" outlet.

Each 1 1/2" x 1 1/2" x 1" CPVC Slip Outlet-Reducing Tee is made in the USA by Thermafit Industries, Inc., a California-based manufacturer of plumbing and fire sprinkler pipe fittings. This outlet-reducing tee has a working pressure rating of 175 PSI at 150F (65C) and is suitable for installation in NFPA 13, NFPA 13D, and NFPA 13R systems where allowed by state and local law.

1 1/2" x 1 1/2" x 1" CPVC Slip Outlet-Reducing Tee is intended for use in light hazard NFPA 13 occupancies, residential NFPA 13R occupancies, and home fire sprinkler systems in accordance with NFPA 13D. This product is UL-listed for use in wet-pipe automatic fire sprinkler systems in combination with UL-listed CPVC products.

1 1/2" x 1 1/2" x 1" CPVC Slip Outlet-Reducing Tee is backed by Thermafit's ten-year warranty from the date of shipment. To find Thermafit-approved CPVC glue, click here. Consult Thermafit's installation manual for minimum curing times, a full list of compatible adhesives, and friction loss allowances. Not suitable for outdoor installation.

Dimensions

CPVC Outlet-Reducing Tee Dimensions

  • M: 2.3125"
  • M1: 1.8750"
  • M2: 2.3125"
  • L: 4.3659"
  • H: 2.1765"

Technical Documents

Click here to view the manual for this 1 1/2" x 1 1/2" x 1" CPVC Slip Outlet-Reducing Tee.