Tyco® TY313 Upright Sprinkler | QR | 5.6K | Black | 175F | 77-370-5-175

SKU:
TY313BL175
Manufacturer Part Number:
77-370-5-175

No reviews yet Write a Review
$12.25

Tyco® TY313 Upright | Black | 175F | 77-370-5-175 | Hero

Tyco® TY313 Upright | Black | 175F | 77-370-5-175 | Hero
Tyco® TY313 Upright | Black | 175F | 77-370-5-175 | Side
Tyco® TY313 Upright | Black | 175F | 77-370-5-175 | Deflector
Play Button

  • Buy 100 - 199 and get 3% off
  • Buy 200 or above and get 7% off

Frequently Bought Together:

Tyco® TY313 Upright | Black | 175F | 77-370-5-175 | Hero
Inc. Tax
Ex. Tax
Overview

Tyco TY-FRB (TY313) Upright Quick Response Fire Sprinkler Head

This Tyco TY-FRB Black Upright Quick Response Fire Sprinkler features a glass bulb activating at 175F (79C) with a 5.6 K-Factor, and 1/2 in. NPT threads. Each upright head features a bronze frame and bronze deflector. The manufacturer part number is 77-370-5-175 and the Sprinkler Identification Number (SIN) is TY313.

The TY-FRB Upright Sprinkler is designed for use in light or ordinary hazard, commercial occupancies such as banks, hotels, and shopping malls. Using a heat-activated glass bulb assembly, this automatic fire sprinkler opens when ambient temperatures reach 175F (79C), drenching the area surrounding a fire to keep it in its place of origin.

Tyco TY-FRB (TY313) Upright QR Fire Suppression Sprinkler Head Listings and Approvals

Each TY-FRB sprinkler is made by Tyco, a global leader in fire-suppression products. This upright fire sprinkler head maintains UL and C-UL Listing, FM Approval, MEA 354-01-E (NYC), VdS Approval, LPCB Ref. No. 094a/06.

The TY313 is a commercial sprinkler and is cULus listed for use when installed in accordance with NFPA 13 requirements for wet pipe sprinkler systems and designed for use in commercial occupancies. This upright sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) FM, and is UL Listed for 250 PSI (17.2 bar) and connects to wet piping systems.

Tyco TY-FRB (TY313) Upright Quick Response Sprinkler Head Installation and Other Information

During installation be aware that over tightening will cause permanent damage to the 1/2 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer approved installation wrench and tighten to a maximum torque of 14 ft-lb (19 N-m). Refer to the data sheet for additional storage and installation information.

This upright sprinkler features a black finish and a 175F (79C) temperature. Finishes options include Brass, White, Black, and Chrome. Signal White Polyester (White) and Jet Black Polyester (Black) are UL Listed as corrosion resistant. Temperature options include 135F (57C), 155F (68C), 175F (79C), 200F (93C), and 286F (141C). Finish and temperature combinations available in the “Options” section at the top of this product page.

TY313 listed accessories include the W-Type 6 sprinkler wrench, manufacturer part number(s) (56-000-6-387). Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These products are available in the “Frequently bought together” products section at the top of this product page. Over the years, Tyco has acquired Central Sprinkler, Gem Sprinkler Company, Grinnell Corporation, and Star Sprinkler Incorporated, and while these brands are no longer available, Tyco has re-designated many of their sprinkler models. Quick-response sprinklers from Gem and Grinnell’s previous Model A line were incorporated into Series TY-FRB. Star’s SG-QR was also re-designated as TY-FRB.

Specifications
QRFS SKU:
TY313BL175
Manufacturer Part Number:
77-370-5-175
Replaces Manufacturer Part Numbers:
57-370-7-175
Manufacturer:
Tyco
SIN:
TY313
Model:
TY-FRB
Head Type:
Upright
Finish:
Black
Finish Detail:
Jet Black Polyester
Size:
1/2 in.
Size Detail:
1/2 in. NPT Sprinkler
K Factor:
5.6K
Response Type:
Quick Response (QR)
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Bronze Frame, Bronze Deflector
Corrosion Resistant:
Yes
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Maximum Working Water Pressure:
175 PSI (FM,UL) 250 PSI (UL)
Length:
1.17 in. (29.72 mm)
Width:
1.17 in. (29.72 mm)
Height:
2 in. (50.8 mm)
Weight:
0.14 lb. (0.06 kg)
Available Box/Pack Quantity:
100
Reviews
No reviews yet