Tyco™ TY4251 Pendent Sprinkler | SR | 8.0K | Brass | 175F | 57-591-1-175

SKU:
TY4251BR175
Manufacturer Part Number:
57-591-1-175
$28.99

FAST SHIPPING: In stock items ship SAME DAY if ordered before 3PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS™ SKU:
TY4251BR175
Manufacturer Part Number:
57-591-1-175
Manufacturer:
Tyco™
SIN:
TY4251
Model:
TY-B
Head Type:
Pendent
Finish:
Brass
Finish Detail:
Natural Brass
Size:
3/4 in.
Size Detail:
3/4 in. NPT
K Factor:
8.0K
Response Type:
Standard Response (SR)
Temperature:
175F
Heat Element:
Glass Bulb
Coverage:
Standard Coverage
Material:
Bronze Frame, Copper Deflector
Corrosion Resistant:
No
May Contain Lead:
Yes
UL Listed:
Yes
FM Approved:
Yes
Other Listings:
cUL Listed, NYC Approved
Maximum Working Water Pressure:
175 PSI
Sourced Location:
USA
Length:
1.25 in. (31.75 mm)
Width:
1.25 in. (31.75 mm)
Height:
2.25 in. (57.15 mm)
Weight:
0.13 lbs. (0.06 kg)

Tyco™ TY4251 Brass 175F SR Pendent 57-591-1-175 Hero Image | QRFS™

Tyco™ TY4251 Brass 175F SR Pendent 57-591-1-175 Hero Image | QRFS™
Tyco™ TY4251 Brass 175F SR Pendent 57-591-1-175 Side Image | QRFS™
Tyco™ TY4251 Brass 175F SR Pendent 57-591-1-175 Alt Side Image | QRFS™
Tyco™ TY4251 Brass 175F SR Pendent 57-591-1-175 Deflector Image | QRFS™
Overview

Tyco™ Model TY-B Pendent Fire Sprinkler Head

Sprinkler Identification Number (SIN): TY4251

This Pendent sprinkler features a Brass finish and a 175°F (79°C) temperature.

This Tyco™ Model TY-B Pendent Fire Sprinkler is a standard response, standard coverage sprinkler, activating at 175°F with a 8.0 K-Factor. Each pendent head features a heat-sensitive 5 mm glass bulb, Standard 3/4 in. NPT threads, and a Bronze frame with Copper deflector.

This is a standard response, standard coverage, pendent sprinkler with a maximum working water pressure of 175 PSI. Using a heat-activated glass bulb, this automatic fire sprinkler opens when ambient temperatures reach 175°F, effectively containing the spread of fire.

The TY4251 is installed as a pendent or recessed pendent using Tyco™’s approved Style 40 recessed escutcheon. Refer to the manufacturer data sheet for installation instructions with the approved Tyco™ escutcheon(s).

Tyco™ Pendent Fire Sprinkler (TY4251) Sprinkler Head Listings and Approvals

Each sprinkler head is made by Tyco™, a global leader in fire protection manufacturing for nearly 100 years. When installed properly, this TY4251 maintains the following listings and approvals: UL, C-UL, FM, LPCB, EAC, VdS
Note: Listings and approvals may vary when installed as a recessed pendent. Always refer to the datasheet for recessed installation-specific approvals.

The Tyco™ Pendent Sprinkler TY4251 is designed for NFPA 13. Apply the listed areas of coverage and minimum water supply requirements as shown in the datasheet. This Pendent sprinkler head has a maximum working pressure of 175 PSI (12.1 BAR) and connects to wet pipe fire protection systems.

Tyco™ TY4251 Automatic Fire Sprinkler Installation and Accessories

During installation, be aware that over-tightening will cause permanent damage to the 3/4 in. NPT threads and/or the fire sprinklers themselves. Use the manufacturer-approved installation wrench and tighten to a maximum torque of 20 ft-lb (26.8 N-m). Refer to the data sheet for additional installation and storage information.

Listed TY4251 Accessories include:

Recessed Escutcheons:

  • Style 40

Sprinkler Wrenches:

  • W-Type 6 Standard Sprinkler Wrench
  • W-Type 7 Recessed Sprinkler Wrench

Commonly purchased with fire sprinkler head cabinets and sprinkler shut off tools. These are available in the corresponding product category sections.

Available Sprinklers

This pendent sprinkler head is also available in Black, Chrome, and White finishes and in 135F, 155F, 200F, 286F, and 360F temperature options.

Reviews
No reviews yet
Product Alternatives