GemLock Grooved Short Pattern Tee
This Grooved x Grooved x Grooved Short Pattern Tee features three 1-1/2 in. connections to be used in grooved pipe systems, including specifically fire sprinkler piping systems, allowing for proper water flow and fast installation. This short tee is available in the following sizes:
1-1/2 in., 2 in., 2-1/2 in., 3 in., 4 in., 5 in., 6 in., 8 in.
You can select your preferred size from the “Options” section at the top of this product page. Accessories compatible with this grooved short tee include other GemLock grooved fittings and Pipe Joint Lubricant.
GemLock is a leader in the grooved pipe market – their grooved fittings are reliable and faster to install than welding threading, or flanging, resulting in drastically lower installation costs comparatively. GemLock grooved fittings provide a clean, consistent, and strong connection for optimal water flow when used with compatible products. The Victaulic grooved fitting equivalent to this product is the Victaulic Short Tee Style 002. Gruvlok fitting equivalent: 7460 Standard Tee.
GemLock Short Pattern Grooved Fittings are designed to Fire Protection Industry standards and sized to improve flow. These Short Pattern Fittings are made of durable, high-strength ductile iron conforming to ASTM A536, with every lot metallurgically tested for compliance. Pressure Ratings of GemLock Grooved Short fittings are tested to a maximum operating pressure of 300 PSI*.
*Maximum pressure includes surges and maximum end loads from all internal and external forces, to which a joint could be subject under normal working conditions. This rating provides a nominal safety factor of 1.5 times working pressure based on standard weight steel pipe. Maximum working pressure may be subjected to a one-time field test of 1.5 times the figures indicated.
GemLock Grooved Short Tee Listings, Approvals, and Other Information
Each grooved short pattern equal tee is made by GemLock, a New York-based manufacturer of fire sprinkler grooved pipe fittings, HVAC, plumbing and grooved tubing. All GemLock grooved piping system fittings are UL Listed and FM Approved. Refer to installations and groove specifications when assembling any grooved product.
All GemLock Ductile Iron tee fittings conform to ASTM A536 Grade 65-45-12. Allowable pipe end separation is for cut groove pipe for roll groove; figures will be one-half of the values listed at time of initial pressurization. Usage of these fittings with the Style 5, 12, and 25 couplings should be evaluated properly due to bolt pad interference of couplings.
Certain GemLock product families and all GemLock Grooved fittings 8 in. and larger are only available upon request and are not available for immediate shipping.
QRFS SKU: |
53-GM-TE-SH-180000 |
Manufacturer Part Number: |
400-210-04080 |
Manufacturer: |
GemLock |
Fitting: |
Tee |
Style: |
Style F107 |
Size: |
1-1/2 in. |
Size Detail: |
1-1/2 in. Grooved x 1-1/2 in. Grooved x 1-1/2 in. Grooved |
UL Listed: |
Yes |
FM Approved: |
Yes |
Rated Working Water Pressure: |
300 PSI |
Finish: |
Orange |
Length: |
4.72 in. (119.89 mm) |
Width: |
2.36 in. (59.94 mm) |
Weight: |
1.5 lb. (0.68 kg) |
Box/Pack Quantity: |
30 |