CPVC Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread with Positioning Ring | Spears FlameGuard™ | R4235-101

SKU:
51-SP-FSA-BR-PR-120800
Manufacturer Part Number:
R4235-101
$9.30
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-FSA-BR-PR-120800
Manufacturer Part Number:
R4235-101
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Adapter
Size:
3/4 in. x 1/2 in.
Size Detail:
3/4 in. x 1/2 in. Head Adapter
Thread Size:
1/2 in.
Thread Material:
Brass
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread with Positioning Ring | Spears FlameGuard™ | R4235-101

CPVC Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread with Positioning Ring | Spears FlameGuard™ | R4235-101
CPVC Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread with Positioning Ring | Spears FlameGuard™ | R4235-101
CPVC Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread with Positioning Ring | Spears FlameGuard™ | R4235-101
CPVC Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread with Positioning Ring | Spears FlameGuard™ | R4235-101
Play Button
Overview

CPVC Female Sprinkler Head Adapter — 3/4 in. x 1/2 in. Brass Thread with Positioning Ring — Spears FlameGuard™ — R4235-101

The Spears FlameGuard™ 3/4-inch x 1/2-inch female sprinkler head adapter with positioning ring connects CPVC pipe to brass sprinkler heads in wet fire sprinkler systems. The adapter features a fire-protection-grade CPVC body and a 1/2-inch brass female thread for secure sprinkler attachment. The integrated positioning ring helps ensure the correct depth and alignment when installing sprinklers in ceiling openings. The socket end joins to CPVC pipe using ASTM F493-compliant solvent cement to form a strong, watertight bond. This fitting is UL Listed and FM Approved for systems following NFPA 13, NFPA 13R, and NFPA 13D standards. It is rated for 175 psi and up to 150°F maximum service temperature.

Install according to Spears FlameGuard™ instructions for cleaning, cementing, and sprinkler alignment. Apply thread sealant approved for use with CPVC and brass materials, and avoid overtightening the sprinkler head. The positioning ring ensures accurate placement for ceiling finishes and escutcheons. This adapter provides a corrosion-resistant, code-compliant connection between CPVC piping and brass sprinklers, ensuring safe and reliable performance in residential and light-hazard fire protection systems.