CPVC Spigot Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-101

SKU:
51-SP-FSA-BR-120800
Manufacturer Part Number:
4238-101
$7.09
Data Sheet Product Data Sheet

Select Variation

FAST SHIPPING: In stock items ship SAME DAY if ordered before 4PM EST via UPS.

RETURNS & REFUNDS: Return unused items in 90 days for a full product refund. Learn more

Specifications
QRFS SKU:
51-SP-FSA-BR-120800
Manufacturer Part Number:
4238-101
Manufacturer:
Spears™
Brand:
FlameGuard™
Material:
Chlorinated Polyvinyl Chloride (CPVC)
Fitting:
Head Adapter
Size:
3/4 in. x 1/2 in.
Size Detail:
3/4 in. x 1/2 in. Head Adapter
Thread Size:
1/2 in.
Thread Material:
Brass
Finish:
Orange
Rated Working Water Pressure:
175 PSI
Rated Working Temperature:
150F
UL Listed:
Yes
FM Approved:
Yes

CPVC Spigot Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-101

CPVC Spigot Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-101
CPVC Spigot Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-101
CPVC Spigot Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-101
CPVC Spigot Female Sprinkler Head Adapter | 3/4 in. x 1/2 in. Brass Thread | Spears FlameGuard™ | 4238-101
Play Button
Overview

CPVC Spigot Female Sprinkler Head Adapter — 3/4 in. x 1/2 in. Brass Thread — Spears FlameGuard™ — 4238-101

The Spears FlameGuard™ 3/4 in. x 1/2 in. spigot female sprinkler head adapter connects CPVC piping to brass sprinkler heads in wet fire sprinkler systems. Made from fire-protection-grade CPVC, this adapter offers high strength, corrosion resistance, and long-term durability. It features a brass female thread insert for secure sprinkler attachment and improved heat resistance. The spigot end is designed for connection to a CPVC socket fitting using ASTM F493-approved solvent cement, creating a watertight, permanent seal. UL Listed and FM Approved, this fitting meets NFPA 13, NFPA 13R, and NFPA 13D installation standards. It is rated for 175 psi and 150°F maximum service temperature, suitable for residential and light-hazard systems.

Follow Spears FlameGuard™ installation instructions for cleaning, solvent cementing, and sprinkler head installation. Use CPVC-compatible sealant and avoid overtightening to prevent thread damage. The brass insert ensures reliable engagement with sprinkler heads and resists thermal expansion under system pressure. This adapter provides a corrosion-resistant, code-compliant, and UL/FM-approved connection for CPVC wet fire sprinkler systems.